Table 34. Memory Ecc Error Handling - Runtime, Redundant Configuration - Intel S7000FC4UR Technical Product Specification

Hide thumbs Also See for S7000FC4UR:
Table of Contents

Advertisement

Intel® Server System S7000FC4UR TPS
Error
System Event Log (SEL)
Scenario
Config = Sparing
CE SEL message
identifying FBDIMM
CE < Threshold1
location
Config = Sparing
CE SEL message
Identifying FBDIMM
CE = Threshold
location
CE Threshold Reached
SEL message
identifying FBDIMM
location
CE Logging Stopped
SEL message
Config = Sparing
No action.
CE > Threshold
Config = Sparing
UE SEL message
identifying FBDIMM
Pre-SFO3
location
UE
Revision 1.0
Table 34. Memory ECC Error Handling — Runtime, Redundant Configuration
DIMM Fault LED
System Fault LED
DIMM LED:
No change
System Fault LED:
No change
DIMM Fault LED: On for
failed FB-DIMM only
System Fault LED:
Green blink.
DIMM Fault LED:
No change
System Fault LED:
No change
DIMM Fault LED:
On for the failed pair of
FBDIMMs in lock-step
mode or for the failed
FBDIMM in single-
channel mode.
System Fault LED:
Amber on
IPMI Memory RAS
Behavior
Set DIMM State:
Set Memory RAS Redun. State:
Set Memory RAS Configuration:
No change
Set DIMM State:
DIMM failure status = Y
DIMM disabled status = Y
DIMM sparing status = N
Set Memory RAS Redundant State:
Domain = 0000b Sparing
State = 01b Non-redundant,
sufficient
Set Memory RAS Configuration:
Sparing Domain Enable = 0
Set DIMM State
Set Memory RAS Redun. State
Set Memory RAS Configuration:
No change
Set DIMM State:
DIMM failure status = Y
Set Memory RAS Redun. State
Set Memory RAS Configuration:
No change
BIOS Initialization
System
Operation
The system continues to operate normally.
The system continues to operate normally. System
transitions to non-redundant mode. The BIOS masks
all correctable memory errors.
Operating system continues to operate normally.
The system asserts an NMI.
135

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents