BMC Functional Specifications
Color
State
Green
Solid on
Ok
Green
~1 Hz blink
Degraded
Amber
~1 Hz blink
Non-fatal
Amber
Solid on
Fatal
Off
N/A
Not ready
260
System Status
System ready
BIOS detected
Unable to use all of the installed memory (more than one DIMM
installed).
Correctable errors over a threshold of 10 and migrating to a
spare DIMM (memory sparing). This indicates that the user no
longer has spared DIMMs, indicating a redundancy lost
condition. The corresponding DIMM LED lights.
In mirrored configuration, when memory mirroring takes place
and system loses memory redundancy.
PCI Express* correctable link errors.
BMC detected
Redundancy loss such as power-supply or fan. Applies only if
the associated platform sub-system has redundancy
capabilities.
CPU disabled
Fan alarm / Fan failure. The number of operational fans should
be more than minimum number needed to cool the system
Non-critical threshold crossed – Temperature, voltage, power
nozzle, power gauge, and PROCHOT1 (Therm Ctrl) sensors.
Battery failure
The system has lost redundancy due to predictive failure
conditions on power supplies
Non-fatal alarm. The system is likely to fail.
BIOS detected
In non-sparing and non-mirroring mode if the threshold of 10
correctable errors is crossed within the window1
PCI Express* uncorrectable link errors.
BMC detected
Critical threshold crossed – Temperature, and PROCHOT
(Therm Ctrl) sensors.
VRD hot-asserted
Minimum number of fans to cool the system not present or
failed
Fatal alarm – system has failed or shutdown.
BIOS detected
DIMM failure when there is one DIMM present, no good
memory present1
Run-time memory uncorrectable error in non-redundant mode1
CPU configuration error (for instance, processor stepping
mismatch).
BMC detected
CPU IERR signal asserted
No CPU present or CPU Configuration Errors
CPU THERMTRIP
No power good – power fault
Power unit redundancy sensor – Insufficient resources offset.
indicates not enough power supplies present.
AC power off
Intel order number E18291-001
Description
1
ESB2 BMC Core TPS
1
1
Revision 1.0