Error Code
0012
System RTC date/time not set
0048
Password check failed
0140
PCI component encountered a PERR error
0141
PCI resource conflict
0146
PCI out of resources error
0191
Processor core/thread count mismatch detected
0192
Processor cache size mismatch detected
0194
Processor family mismatch detected
Processor Intel(R) UPI link frequencies unable to
0195
synchronize
0196
Processor model mismatch detected
0197
Processor frequencies unable to synchronize
5220
BIOS Settings reset to default settings
5221
Passwords cleared by jumper
5224
Password clear jumper is Set
8130
CPU 0 disabled
8131
CPU 1 disabled
8160
CPU 0 unable to apply microcode update
8161
CPU 1 unable to apply microcode update
8170
CPU 0 failed Self-Test (BIST)
8171
CPU 1 failed Self-Test (BIST)
8180
CPU 0 microcode update not found
8181
CPU 1 microcode update not found
8190
Watchdog timer failed on last boot.
8198
OS boot watchdog timer failure.
8300
Baseboard Management Controller failed self-test.
8305
Hot Swap Controller failure
83A0
Management Engine (ME) failed self-test.
83A1
Management Engine (ME) Failed to respond.
84F2
Baseboard management controller failed to respond
84F3
Baseboard Management Controller in Update Mode.
Baseboard Management Controller Sensor Data Record
84F4
empty.
84FF
System Event Log full
Memory component could not be configured in the
85FC
selected RAS mode
8501
Memory Population Error
8502
PMem invalid DIMM population found on the system.
8520
Memory failed test/initialization CPU0_DIMM_A1
8521
Memory failed test/initialization CPU0_DIMM_A2
8522
Memory failed test/initialization CPU0_DIMM_A3
138

Table 12. POST Error Messages and Handling

Error Message
Action message
Put right password.
Enable Memory Mapped I/O above 4
GB item at SETUP to use 64-bit MMIO.
Use identical CPU type.
Use identical CPU type.
Use identical CPU type.
Use identical CPU type.
Use identical CPU type.
Recommend reminding user to install
BIOS password as BIOS admin
password is the master keys for
several BIOS security features.
Update right SDR.
Clear SEL through EWS or SELVIEW
utility.
Plug DIMM at right population.
Populate valid POR PMem DIMM
population.
Remove the disabled DIMM.
Remove the disabled DIMM.
Remove the disabled DIMM.
Type
Major
Major
Major
Major
Major
Fatal
Fatal
Fatal
Fatal
Fatal
Fatal
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Minor
Major
Major
Major
Major
Major
Major
Major
Major
Major
Minor
Major
Major
Major
Major
Major
Major