HSC Functional Specifications
29.7.3
Enclosure Temperature Sensing
A temperature sensor device is connected to the HSC via a private I
monitors the enclosure temperature. The temperature can be read via SAF-TE, SES2, and IPMI
commands. Programmable temperature thresholds are provided via IPMI commands. The HSC
can be configured to issue an event message on the IPMB when a temperature threshold is
crossed.
29.8 Slot Status to Fault Light State Mapping
The fault light state for each internal drive slot state is maintained by the hot-swap controller.
The HSC supports various OEM LED models.
Device
Identify
Inserted
X
0
X
0
X
0
1
0
0
0
X
0
X
1
X = don't care
Fast Blink = ~2.5 Hz
Slow Blink = ~1 Hz.
306
Table 109. Slot Status to Fault Light State Mapping
Slot Status
Device
Rebuild
Rebuilding
Stopped
0
0
0
0
0
0
1
0
1
0
X
1
X
X
Intel order number E18291-001
Device
Predicted
Faulty
Fault
0
0
Off
0
1
Slow blink
1
X
Steady on
X
X
Slow blink
X
X
Fast blink
X
X
Fast blink
X
X
Fast blink
Intel® Server System S7000FC4UR
2
C bus. This device
Fault Light State
Fault Light
Indicated Condition
No errors
Predicted Fault
Faulted Slot
Rebuild
Rebuild on empty
slot
Rebuild Interrupted
Identify Slot
Revision 1.0