Section 5. Troubleshooting
Programmable Maintenance Tool

Programming

You can change certain parameters using the
PMT. See Table 5-7. All changes occur in "real
time"; the parameters can be changed while the
truck is in operation.
1. Turn the key switch OFF and disconnect
the battery connector.
2. Remove the tractor cover.
Connect the PMT to the traction power
3.
amplifier.
4. Connect the battery and turn the key
switch ON.
5. Press the program key to enter the
Program mode.
Press either scroll display key until the
6.
parameter you want is the top line of the
display. See Table 5-7.

Traction Power Amplifier Parameters

Table
M 3 RESTRAINT
Toyota Orderpicker Model 7BPUE 15 Service Manual
7. Press either change value key until the
setting you want is displayed. The
parameter is now set a t the value you
selected.
8. If the display stops changing and you want
to go further, press the more info key. If
the display shows "Min. Limit" or "Max
Limit," you have reached the factory set
limit for that parameter.
N
: The parameter may be dependent on
O TE
another parameter. If so, the display will
show this information. Changing the
related parameter may allow you to
change the setting further.
See "Definitions" on page 5- 17.
neutral with the deadman switches closed.
With neutral braking set a t 0%, the truck coasts
to a stop when the throttle is in neutral
(released). There is no plugging force applied.
When set to
ing force when the throttle is in neutral
00700-CL222-05, 1 5 March 2005