Toyota Orderpicker Model 7BPUE 15 Service Manual
Electrical Components
Install new contact spring over insulator
3.
bushing.
Install new fiber washer over rod assembly
4.
shaft.
5. Secure movable tip assembly with nut on
top of core and rod assembly shaft.
6. Install new stationary contactor tips
with tips facing up.
7-75.
Figure
Contactor Assembly
Make sure cable posts face up, and are
on same side as contactor coil spade
terminals.
Make sure studs on lower retaining
block lock into holes in contact tip bar.
7. Install upper retainer blocks (2). Studs on
blocks will lock into holes in contactor
tips. See Figure 7-75.
N
: Grooves on the retainer blocks face the
O TE
inside.
Secure upper retainer blocks with nylon
8.
nuts.
00700-CL222-05, 1 5 March 2005
Section 7. Component Procedures
Contactor Tip Replacement