Memory Events
Messages and Descriptions
Oracle ILOM Event Message: event fault.memory.intel.dimm.disable-quadrank "Memory
channel is populated with too many quad-rank memory DIMMs."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.disable-quadrank "Memory
channel is populated with too many quad-rank memory DIMMs."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.population-invalid "Memory
DIMM is improperly populated or is a type that is not compatible with other DIMMs installed."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.out-of-order "The memory
DIMMs in a channel are not populated in sequential order."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.category-unknown "Memory
DIMM is of an unknown type or category."
Severity and Description: Informational; A memory component fault has been cleared.
Related Information
"System Chassis Components" on page 231
"Cooling Unit Components" on page 233
254
Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018
Component Name
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Exadata X5-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents