Messages and Descriptions
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.incompatible-maxranks "The
number of ranks allowed on a memory channel has been exceeded."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.incompatible-maxranks "The
number of ranks allowed on a memory channel has been exceeded."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.incompatible-quadrank "An
invalid quad-rank memory DIMM configuration has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message:event fault.memory.intel.dimm.incompatible-quadrank "An
invalid quad-rank memory DIMM configuration has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.numranks-unsupported "A
memory DIMM with an unsupported number of ranks has been detected."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.numranks-unsupported "A
memory DIMM with an unsupported number of ranks has been detected."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Oracle ILOM Event Message: event fault.memory.intel.dimm.speed-slow "A memory DIMM
has been detected that is unable to run at speeds required by the platform."
Severity and Description: Major; A memory component is suspected of causing a fault.
SNMP Trap: sunHwTrapMemoryFaultCleared
Oracle ILOM Event Message: event fault.memory.intel.dimm.speed-slow "A memory DIMM
has been detected that is unable to run at speeds required by the platform."
Severity and Description: Informational; A memory component fault has been cleared.
SNMP Trap: sunHwTrapMemoryFault
Component Name
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
/SYS/MB/P[0-x]/D[0-11]
Monitoring Components and Identifying SNMP Messages
Memory Events
253
Need help?
Do you have a question about the Exadata X5-2 and is the answer not in the manual?
Questions and answers