Remove The Sun Storage 12 Gb/S Sas Pcie Raid Hba Card - Oracle Exadata X5-2 Service Manual

High capacity storage server
Hide thumbs Also See for Exadata X5-2:
Table of Contents

Advertisement

Remove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card

This section covers the following topics:
"Remove the Sun Storage 12 Gb/s SAS PCIe RAID HBA Card" on page 124
"Install the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card" on page 127
Related Information
"Servicing SAS Cables" on page 118
Remove the Sun Storage 12 Gb/s SAS PCIe RAID
HBA Card
1.
Prepare the server for service.
a.
Power off the server and disconnect the power cords from the power
supplies.
See
b.
Extend the server to the maintenance position.
See
c.
Attach an antistatic wrist strap.
See
Remove the server top cover.
d.
See
Remove the super capacitor from the chassis.
2.
a.
Grasp both ends of the cable connector, press in on the release latch, and
then unplug the connector [1].
The HBA super capacitor is secured to the air baffle by a reclosable fastener, which allows
it to be easily removed and replaced.
b.
To separate the HBA super capacitor from the air baffle, place your finger
under the rear of the super capacitor and lift up [2].
124
Oracle Exadata Storage Server X5-2 High Capacity Service Manual • January 2018
"Powering Down the Server" on page
"Extend the Server to the Maintenance Position" on page
"Electrostatic Discharge Safety" on page
"Remove the Server Top Cover" on page
51.
55.
48.
58.

Advertisement

Table of Contents
loading

Table of Contents