The following table lists the holding registers for the "A" Group Standard Functions.
Func.
Code
A001
A002
A003
A203
A004
A204
A005
A011
A012
A013
A014
A015
A016
More user manuals on
Name
R/W
Frequency source
R/W Five options; select codes:
setting
Run command source
R/W Three options; select codes:
setting
Base frequency setting R/W Settable from 30 Hz to the
Base frequency setting,
R/W Settable from 30 Hz to the 2nd
2nd motor
Maximum frequency
R/W Settable from the base frequency
setting
Maximum frequency
R/W Settable from the 2nd base
setting, 2nd motor
[AT] selection
R/W Five options, select codes:
O–L input active range
R/W The output frequency
start frequency
O–L input active range
R/W The output frequency
end frequency
O–L input active range
R/W The starting point (offset) for the
start voltage
O–L input active range
R/W The ending point (offset) for the
end voltage
O–L input start
R/W Two options; select codes:
frequency enable
External frequency
R/W Range n = 1 to 16, where n =
filter time constant
ManualsBase.com
List of Holding Registers
Description
00...Keypad potentiometer
01...Control terminal
02...Function F001 setting
03...ModBus network input
10...Calculate function output
01...Control terminal
02...Run key on keypad, or
digital operator
03...ModBus network input
maximum frequency
maximum frequency
up to 400 Hz
frequency up to 400 Hz
00... Select between [O] and [OI]
at [AT]
02... Select between [O] and
keypad potentiometer
03... Select between [OI] and
keypad potentiometer
04... Only [O] input active
05... Only [OI] input active
corresponding to the analog
input range starting point,
Range is 0.0 to 400.0
corresponding to the analog
input range ending point, range
is 0.0 to 400.0
active analog input range, range
is 0. to 100
active analog input range, range
is 0. to 100.
00...Use offset (A011 value)
01...Use 0 Hz
number of samples for average.
Set 17 to use 16-samples for avg.,
plus deadband +0.1/-0.2Hz
B−25
Network Data
Reg.
Range
Res.
1019h
0 to 3, 10
101Ah
1, 2, 3
101Bh 30 to max.
1 Hz
freq.
150Ch 30 to max.
1 Hz
freq.2
101Ch
30 to 400
1 Hz
150Dh
30 to 400
1 Hz
101Dh
0, 2, 3,
4, 5
1020h
0 to 4000
0.1 Hz
1022h
0 to 4000
0.1 Hz
1023h
0 to 100
1 %
1024h
0 to 100
1 %
1025h
0, 1
1026h
1 to 17
1 sample