Hitachi X200-002SFE/NFU Instruction Manuals page 82

X200 series. single-phase input 200v class. three-phase input 200v class. three-phase input 400v class.
Table of Contents

Advertisement

3−8
Local Monitoring During Network Operation
The X200 inverter's serial port may be connected to a network or to an external digital
operator. During those times, the inverter keypad keys will not function (except for the
Stop key). However, the inverter's 4-digit display still provides the Monitor Mode
function, displaying any of the parameters D001 to D007. Function B089, Monitor
Display Select for Networked Inverter, determines the particular D00x parameter
displayed. Refer to table below.
When monitoring the inverter during network operation, please note the following:
• The inverter display will monitor D00x functions according to B089 setting when...
• During network operation, the inverter keypad will also display error codes for
• The Stop key can be disabled, if you prefer, by using function B087.
More user manuals on
B089 Monitor Display Select for Networked Inverter
Option
Monitor
Code
Code
01
D001
Output frequency monitor
02
D002
Output current monitor
03
D003
Rotation direction monitor
04
D004
Process variable (PV),PID feedback monitor
05
D005
Intelligent input terminal status
06
D006
Intelligent output terminal status
07
D007
Scaled output frequency monitor
The OPE/485 DIP switch is set to the "485" position, or
A device is already connected to the inverter's serial port at inverter powerup.
inverter trip events. Use the Stop key or inverter Reset function to clear the error.
Refer to
"Error
Codes" on page 6-5 to interpret the error codes.
ManualsBase.com
Monitor Function Name

Advertisement

Table of Contents
loading

Table of Contents