The following table lists holding registers for the "D" Group Monitor Functions.
Func.
Code
D001
D002
D003
D004
(high)
D004
(low)
D005
D006
D007
(high)
D007
(low)
D013
D016
(high)
D016
(low)
D017
(high)
D017
(low)
D018
D080
D102
D104
Note 1:
More user manuals on
Name
R/W
Output frequency
R
monitor
Output current
R
monitor *1
Rotation direction
R
monitor
Process Variable (PV),
R
PID feedback monitor
R
Intelligent input
R
terminal status
Intelligent output
R
terminal status
Scaled output
R
frequency monitor
R
Output voltage
R
monitor
Cumulative operation
R
RUN time monitor
R
Cumulative power-on
R
time monitor
R
Fin temperature
R
monitor
Trip counter
R
DC voltage monitor
R
Electronic thermal
R
monitor
Assume that the inverter current rating is 1000 (for D002).
ManualsBase.com
List of Holding Registers
Description
Real-time display of output
frequency to motor, from 0.0 to
400.0 Hz
Filtered display of output
current to motor (100 ms
internal filter time constant),
range is 0 to 200% of inverter
rated current
Three different indications:
00...Stop
01...Forward
02...Reverse
Displays the scaled PID process
variable (feedback) value (A075
is scale factor), range is 0.00 to
9999.00
Displays the state of the
intelligent input terminals [x],
Bit 0 = [1] to Bit 4 = [5]
Displays the state of the
intelligent output terminals [x],
Bit 0 = [11], Bit 1 = (Don't Care),
Bit 2 = [AL]
Displays the output frequency
scaled by the constant in B086.
Decimal point indicates range:
0.00 to 39960.00
Voltage of output to motor, range
is 0.00 to 200.00%
Displays total time the inverter
has been in RUN mode in hours.
Range is 0 to 999999
Displays total time the inverter
has been in RUN mode in hours.
Range is 0 to 999999
Display the Fin temperature in
0.0~200.0°C
Number of trip events, range is 0
to 65535
Voltage of DC bus inside
inverter,Range is 0.0 to 999.9
Accumulated value of electronic
thermal detection, range is from
0.0 to 100.0
Network Data
Reg.
Range
Res.
1002h
0 to 4000
0.1 Hz
1003h
0 to 2000
0.1%
1004h
0,1,2
1005h
0 to
0.00%
999900
times
const.
1006h
1007h
0 to 63
1008h
0 to 7
1009h
0 to
0.01 Hz
3996000
times
const.
100Ah
100Ch
0 to
0.01%
20000
100Eh
0 to
1 hour
999999
100Fh
1010h
0 to
1 hour
999999
1011h
116Ah
0 to 2000
0.1°C
0011h 0 to 65535
1 trip
event
116Ch
0 to 9999
0.1 V
116Dh
0 to 1000
0.1 %