Func.
Code
B080
B082
B083
B084
B085
B086
B087
More user manuals on
"B" Function
Name /
SRW Display
[AM] analog signal gain
AM-Adj
00100%
Start frequency adjustment
fmin
0000.5Hz
Carrier frequency setting
Carrier
0003.0
Initialization mode
(parameters or trip history)
INIT Mode
TRP
Country for initialization
INIT Slct
EU
Frequency scaling conversion
factor
Cnv Gain
0001.0
STOP key enable
STP Key
ON
ManualsBase.com
Description
Adjust of analog output at
terminal [AM],
range is 0 to 255
Sets the starting frequency for
the inverter output, range is 0.5
to 9.9 Hz
Sets the PWM carrier (internal
switching frequency), range is 2.0
to 12.0 kHz
Select the type of initialization to
occur, three option codes:
00...Trip history clear
01...Parameter initialization
02... Trip history clear and
parameter initialization
Select default parameter values
for country on initialization,
three option codes:
00...Japan
01...Europe
02...US
Specify a constant to scale the
displayed frequency for D007
monitor, range is 0.1 to 99.9
Select whether the STOP key on
the keypad is enabled,
two option codes:
00...Enabled
01...Disabled
3−41
Defaults
Run
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
100.
100.
0.5
0.5
Hz
3.0
3.0
kHz
00
00
01
02
1.0
1.0
00
00

Advertisement