General Specifications

The following table applies to all X200 inverters.
Protective housing *1
Control method
Carrier frequency
Output frequency range *4
Frequency accuracy
Frequency setting resolution
Volt./Freq. characteristic
Overload capacity
Acceleration/deceleration time
Input
signal
Output
signal
Alarm output contact
Other functions
Protective function
Operating
environment
Coating color
Options
More user manuals on
Item
IP20
Sinusoidal Pulse Width Modulation (PWM) control
2kHz to 12kHz (default setting: 3kHz)
0.5 to 400Hz
Digital command: 0.01% of the maximum frequency
Analog command: 0.4% of the maximum frequency (25°C ± 10°C)
Digital: 0.1Hz; Analog: max. frequency/1000
V/f control (constant torque, reduced torque)
150% rated current for 1 minute
0.01 to 3000 seconds, linear and S-curve accel/decel, second
accel/decel setting available
Freq.
Operator panel Up and Down keys / Value settings
setting
Potentiometer
Analog setting
External signal
0 to 10 VDC (input impedance 10k Ohms), 4 to 20mA (input
*9
impedance 250 Ohms), Potentiometer (1k to 2k Ohms, 2W)
FWD/
Operator panel Run/Stop (Forward/Reverse run change by command)
REV run External signal Forward run/stop, Reverse run/stop
Intelligent input
FW (forward run command), RV (reverse run command), CF1~CF4
terminal
(multi-stage speed setting), JG (jog command), DB (external
braking), SET (set second motor), 2CH (2-stage accel./decel.
command), FRS (free run stop command), EXT (external trip), USP
(startup function), SFT (soft lock), AT (analog current input select
signal), RS (reset), PTC (thermistor thermal protection), STA (start),
STP (stop), F/R (forward/reverse), PID (PID disable), PIDC (PID
reset), UP (remote control up function), DWN (remote control down
function), UDC (remote control data clearing), OPE (operator
control), ADD (add frequency enable), F-TM (force terminal mode),
RDY (Run ready), SP-SET (Special set) , EMR (Safe Stop)
Intelligent output
RUN (run status signal), FA1,FA2 (frequency arrival signal),
terminal
OL (overload advance notice signal), OD (PID error deviation
signal), AL (alarm signal), Dc (analog input disconnect detect),
FBV (PID two-stage control output), NDc (network detection signal),
LOG (Logic output), ODc (comm. watchdog error), LOC (Low load)
Frequency monitor
Analog output; Select output frequency or output current monitor
ON for inverter alarm (1c contacts, both normally open or closed
avail.)
AVR function, curved accel/decal profile, upper and lower limiters,
16-stage speed profile, fine adjustment of start frequency, carrier
frequency change (2 to 12kHz) *10, frequency jump, gain and bias
setting, process jogging, electronic thermal level adjustment, retry
func., trip history monitor, 2nd setting select, fan ON/OFF selection.
Over-current, over-voltage, under-voltage, overload, extreme high
temperature, CPU error, memory error, ground fault detection at
startup, electronic thermal
Temperature
Operating (ambient): -10 to 40°C(*10), / Storage: -25 to 70°C(*11)
Humidity
20 to 90% humidity (non-condensing)
Vibration *12
5.9m/s
Location
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Blue
Remote operator unit, copy unit, cables for the units, braking unit,
braking resistor, AC reactor, DC reactor, noise filter