Hitachi X200-002SFE/NFU Instruction Manuals page 262

X200 series. single-phase input 200v class. three-phase input 200v class. three-phase input 400v class.
Table of Contents

Advertisement

Func.
Code
B133
DC bus AVR
selection
B134
Threshold voltage of
DC bus AVR setting
B140
Over-current trip
suppression
B150
Carrier mode
B151
Selection of RDY
function
Note 1:
More user manuals on
Name
R/W
R/W Two option codes:
00...Disabled
01...Enabled
R/W Setting of threshold voltage of DC bus
voltage to start DC bus AVR function.
Range is:
200V class...330 to 395
400V class...660 to 790
R/W Two option codes:
00...Disable
01...Enable
R/W Automatically reduces the carrier
frequency as the ambient temperature
increases.
00...Disable
01...Enable
R/W Select Ready function.
00...Disable
01...Enable
Assume that the inverter current rating is 10000 (for B013/B213).
ManualsBase.com
List of Holding Registers
Description
B−35
Network Data
Reg.
Range
Res.
1176h
0, 1
1177h 330 to 395,
1 V
660 to 790
10F7h
0, 1
10F8h
0, 1
10F9h
0, 1

Advertisement

Table of Contents
loading

Table of Contents