Analog Signal Calibration Settings
The functions in the following table
configure the signals for the analog
input
settings
current/voltage
characteristics – only the zero and
span (scaling) of the signals.
Func.
Code
C081
C082
C086
NOTE: When you restore factory default settings, the values will change to those listed
above. Be sure to manually reconfigure the values for your application, if needed, after
restoring factory defaults.
More user manuals on
terminals.
Note
do
not
change
or
"C" Function
Name /
SRW Display
O input span calibration
O-ADJ
0100.0%
OI input span calibration
OI-ADJ
0100.0%
AM offset calibration
AM OFFST
0000.0V
ManualsBase.com
Freq setpoint
Max. freq
that
these
the
sink/source
Max. freq /2
0
0V, 4mA
Description
Scale factor between the external
frequency command on terminals
L–O (voltage input) and the
frequency output,
range is 0.0 to 200%
Scale factor between the external
frequency command on terminals
L–OI (voltage input) and the
frequency output,
range is 0.0 to 200%
Offset adjustment of AM output.
Range is 0.0 to 10.0
Adjust together with B080 (AM
gain adjustment)
- See
page 3-40, 4-55
for details.
200%
100%
50%
5V, 12mA
10V, 20mA
Defaults
Run
Mode
-FE
-FU
Edit
(EU)
(USA)
100.0 100.0
100.0 100.0
0.0
0.0
3−61
Units
%
%
V

Advertisement

Table of Contents
loading

Table of Contents