Func.
Code
B031
NOTE: To disable parameter editing when using B031 lock modes 00 and 01, assign the
[SFT] function to one of the intelligent input terminals.
See
More user manuals on
"B" Function
Name /
SRW Display
Software lock mode selection
S-Lock
MD1
"Software Lock" on page
ManualsBase.com
Description
Prevents parameter changes, in
four options, option codes:
00...all parameters except B031
are locked when [SFT]
terminal is ON
01...all parameters except B031
and output frequency F001
are locked when [SFT]
terminal is ON
02...all parameters except B031
are locked
03...all parameters except B031
and output frequency F001
are locked
10...High level access including
B031
See appendix C
for the accessible
parameters in this mode.
4-21.
3−37
Defaults
Run
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
01
01