Miscellaneous Functions
The following table contains miscellaneous functions not in other function groups.
Func.
Code
C091
C101
C102
CAUTION: Do not change Debug mode for safety reasons. Otherwise unexpected
performances may occur.
More user manuals on
"C" Function
Name /
SRW Display
Debug mode enable *
DBG Slct
OFF
Up/Down memory mode
selection
UP/DWN
NO-STR
Reset selection
RS Slct
ON
ManualsBase.com
Description
Displays debug parameters.
Two option codes:
00...Disable
01...Enable <Do not set>
(for factory use)
Controls speed setpoint for the
inverter after power sycle.
Two option codes:
00...Clear last frequency (return to
default frequency F001)
01...Keep last frequency adjusted
by UP/DWN
Determines response to Reset
input [RS].
Three option codes:
00...Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01...Cancel trip state at signal
OFF transition, stops inverter
if in Run Mode
02...Cancel trip state at input ON
transition, no effect if in Run
Mode
Defaults
Run
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
00
00
00
00
00
00