Hitachi X200-002SFE/NFU Instruction Manuals page 137

X200 series. single-phase input 200v class. three-phase input 200v class. three-phase input 400v class.
Table of Contents

Advertisement

Output Logic and Timing
Logic Output Function – The inverter has a built-in logic output feature. You can select
any two of the other nine intelligent output options for internal inputs. Then, configure
the logic function to apply the logical AND, OR, or XOR (exclusive OR) operates as
desired to the two inputs. The terminal symbol for the new output is [LOG]. Use C021,
or C026 to route the logical result to terminal [11] or the relay terminals.
The following table shows all four possible input combinations with each of the three
available logic operations.
Func.
Code
C141
C142
C143
More user manuals on
Intelligent outputs
used as internal
inputs:
RUN, FA1, FA2,
OL, OD, AL, Dc,
FBV, NDc, ODc,
LOC
RUN, FA1, FA2,
OL, OD, AL, Dc,
FBV, NDc, ODc,
LOC
Input Status
[LOG] Output State
A
B
AND
0
0
0
0
1
0
1
0
0
1
1
1
"C" Function
Name /
SRW Display
Input A select for logic
output
LogicOut1
RUN
Input B select for logic
output
LogicOut2
FA1
Logic function select
LogicOPE
AND
ManualsBase.com
C141
Input A
Logic function
C142
AND, OR, XOR
Input B
OR
XOR
0
0
1
1
1
1
1
0
Description
11 programmable functions
available for logic (discrete)
outputs
00...RUN
01...FA1
02...FA2
03...OL
04...OD
05...AL
06...Dc
07...FBV
08...NDc
09...LOG
10...ODc
43...LOC
Applies a logic function to calculate
[LOG] output state,
Three options:
00...[LOG] = A AND B
01...[LOG] = A OR B
02...[LOG] = A XOR B
3−63
C021
11
C026
AL1
AL0
AL2
Run
Defaults
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
00
00
01
01
00
00