4−22
Analog Input Current/Voltage Select
The [AT] terminal selects whether the inverter uses the voltage [O] or current [OI]
input terminals for external frequency control. When intelligent input [AT] is ON, you
can set the output frequency by applying a current input signal at [OI]-[L]. When the
[AT] input is OFF, you can apply a voltage input signal at [O]-[L] to set the output
frequency. Note that you must also set parameter A001 = 01 to enable the analog
terminal set for controlling the inverter frequency.
Option
Code
16
Valid for inputs:
Required settings
Notes:
• If the [AT] option is not assigned to any
intelligent input terminal, then inverter
recognizes [AT] = OFF in following table.
• Be sure to set the frequency source setting
A001=01 to select the analog input terminals.
Combination of A005 setting and [AT] input for analog input activation.
Note that you cannot give [O] and [OI] input at the same time on X200 inverter.
More user manuals on
Terminal
Function Name
Symbol
AT
Analog Input
Voltage/Current
Select
C001~C005
A001 = 01
A005
[AT] Input
Analog Input Configuration
ON
02
OFF
ON
03
OFF
04
(ignored)
05
(ignored)
ManualsBase.com
State
ON
See the table down below
OFF
Example (default input configuration shown
for –FU models; –FE models require input
configuration—see
page
5
4
AM H
O OI L
+ -
See I/O specs on
page 4–6.
Keypad Pot
[O]
Keypad Pot
[OI]
[O]
[OI]
Description
3–49):
AT
L PCS P24
3
2
1
4-20 mA
0-10 V