"C" Group: Intelligent Terminal Functions

The five input terminals [1], [2], [3], [4], and [5] can be configured for any of 31 different
functions. The next two tables show how to configure the five terminals. The inputs are
logical, in that they are either OFF or ON. We define these states as OFF=0, and ON=1.
The inverter comes with default options for the five terminals. These settings are
initially unique, each one having its own setting. Note that European and US versions
have different default settings. You can use any option on any terminal, and even use
the same option twice to create a logical OR (though usually not required).
NOTE: Terminal [5] has the ability to be a logical input, and to be an analog input for a
thermistor device when PTC function (option code 19) is assigned to that terminal.
Input Terminal Configuration
Functions and Options – The
twenty eight options to any of the five logic inputs for the X200 inverters. The functions
C001 through C005 configure the terminals [1] through [5] respectively. The "value" of
these particular parameters is not a scalar value, but it is a discrete number that selects
one option from many available
For example, if you set function C001=00, you have assigned option 00 (Forward Run) to
terminal [1]. The option codes and the specifics of how each one works are in
Func.
Code
C001
C201
C002
C202
C003
C203
C004
C204
C005
C205
More user manuals on
"C" Function
Name /
SRW Display
Terminal [1] function
IN-TM 1
FW
Terminal [1] function,
2nd motor
2IN-TM 1
FW
Terminal [2] function
IN-TM 2
RV
Terminal [2] function,
2nd motor
2IN-TM 2
RV
Terminal [3] function
IN-TM 3
AT
Terminal [3] function,
2nd motor
2IN-TM 3
AT
Terminal [4] function
IN-TM 4
USP
Terminal [4] function,
2nd motor
2IN-TM 2
USP
Terminal [5] function
IN-TM 5
2CH
Terminal [5] function,
2nd motor
IN-TM 5
2CH
ManualsBase.com
function codes
in the following table let you assign one of
options
.
Description
Select input terminal [1] function, 30
options(see next section)
Select input terminal [1] function for
2nd motor, 30 options(see next
section)
Select input terminal [2] function, 30
options(see next section)
Select input terminal [2] function for
2nd motor, 30 options(see next
section)
Select input terminal [3] function, 30
options(see next section)
Select input terminal [3] function for
2nd motor, 30 options(see next
section)
Select input terminal [4] function, 30
options(see next section)
Select input terminal [4] function for
2nd motor, 30 options(see next
section)
Select input terminal [5] function, 30
options(see next section)
Select input terminal [5] function for
2nd motor, 30 options(see next
section)
3−49
Chapter
4.
Run
Defaults
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
00
00
[FW]
[FW]
01
01
[RV]
[RV]
02
16
[CF1]
[AT]
02
16
[CF1]
[AT]
03
13
[CF2]
[USP]
18
18
[RS]
[RS]

Advertisement

Table of Contents
loading

Table of Contents