"H" Group: Motor Constants Functions

The "H" Group parameters configure the
inverter for the motor characteristics. You must
manually set H003 and H004 values to match
the motor. Parameter H006 is factory-set. If you
want to reset the parameters to the factory
default
"Restoring Factory Default Settings" on page 6-
8. Use A044 to select the torque control
algorithm as shown in the diagram.
Func.
Code
H003
H203
H004
H204
H006
H206
More user manuals on
settings,
use
the
"H" Function
Name /
SRW Display
Motor capacity
AUX K
0.4 kW
Motor capacity, 2nd motor
2AUXK
0.4 kW
Motor poles setting
AUX P
4p
Motor poles setting, 2nd
motor
2AUXP
4p
Motor stabilization
constant
AUX KCD
100
Motor stabilization
constant, 2nd motor
2AUXKCD
100
ManualsBase.com
Inverter Torque Control Algorithms
V/f control,
constant torque
procedure
in
V/f control,
variable torque
Description
Eight selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7
Eight selections:
0.2/0.4/0.55/0.75/1.1/1.5/2.2/3.7
Four selections:
2 / 4 / 6 / 8
Four selections:
2 / 4 / 6 / 8
Motor constant (factory set),
range is 0 to 255
Motor constant (factory set),
range is 0 to 255
3−65
A044
00
Output
01
Defaults
Run
Mode
-FE
-FU
Units
Edit
(EU)
(USA)
Specified by
kW
the capacity
of each
inverter
kW
model
4
4
poles
4
4
poles
100
100
100
100