Logic Output Function
The Logic Output Function uses the inverter's built-in logic feature. You can select any
two of the other nine intelligent output options for internal inputs (use C141 and C142).
Then, use C143 to configure the logic function to apply the logical AND, OR, or XOR
(exclusive OR) operator as desired to the two inputs.
Intelligent outputs used
as internal inputs:
More user manuals on
Master
Slave
Watchdog timer
C077 = xx.xx sec.
[NDc]
Alarm
C076 = 00 or 01
C141
RUN, FA1, FA2,
Input A
OL, OD, AL, Dc,
FBV, NDc
C142
RUN, FA1, FA2,
Input B
OL, OD, AL, Dc,
FBV, NDc
ManualsBase.com
Time-out
Logic function
[LOG]
AND, OR, XOR
Input Status
[LOG] Output State
A
B
AND
0
0
0
0
1
0
1
0
0
1
1
1
4−49
OR
XOR
0
0
1
1
1
1
1
0