Func.
Code
C144
Terminal [11] ON delay
C145
Terminal [11] OFF delay R/W Range is 0.0 to 100.0 sec.
C148
Output relay ON delay
C149
Output relay OFF delay
Note 1:
The following table lists the holding registers for the "H" Group Motor Constants.
Func.
Code
H003 Motor capacity
H203 Motor capacity, 2nd
motor
H004 Motor poles setting
H204 Motor poles setting, 2nd
motor
H006 Motor stabilization
constant
H206 Motor stabilization
constant, 2nd motor
More user manuals on
Name
R/W
R/W Range is 0.0 to 100.0 sec.
R/W Range is 0.0 to 100.0 sec.
R/W Range is 0.0 to 100.0 sec.
Assume that the inverter current rating is 10000 (for C041).
Name
R/W
R/W
R/W
R/W
R/W
R/W
R/W
ManualsBase.com
List of Holding Registers
Description
List of Holding Registers
Description
0...0.20kW
1...0.37kW
2...0.40kW
3...0.55 kW
4...0.75 kW
5...1.10 kW
6...1.50 kW
7...2.2 kW
8...3.0 kW
9...3.7 kW
10...4.0 kW
11...5.5 kW
12...7.5 kW
13...11.0kW
Four selections:
2 / 4 / 6 / 8
Motor constant (factory set),
range is 0 to 255
B−39
Network Data
Reg.
Range
Res.
1153h 0 to 1000 0.1 sec
1154h 0 to 1000 0.1 sec
1157h 0 to 1000 0.1 sec
1158h 0 to 1000 0.1 sec
Network Data
Reg.
Range
Res.
1165h
0 to 13
1541h
0 to 13
1166h 2, 4, 6, 8
1 pole
1542h 2, 4, 6, 8
1 pole
1168h
0 to 255
1
1544h
0 to 255
1