Chapter 14, Using the Secondary Panes in Xgig TraceView
When creating extractions from a trace, if only the exchange ending timestamp is within the
extraction time slot and beginning timestamp is not, wire events or PDUs at the beginning of the
exchange are not extracted. In such cases, the error message, "Not saved" is shown as decode in
the summary column for the missing wire events.
When an exchange contains more than 100 frames or PDUs, first 99 frames are displayed under an
exchange and there is a placeholder which shows how many more frames are there in that
exchange.
If only one port is explicitly opened from the buffer, the corresponding .xpt file will be
automatically opened if it is available. If a .trc file is opened, the corresponding .xpt file is not
automatically opened even if it is available.
There are no changes to the display or decodes in the other grids due to the presence or absence of
Exchanges View
Tx Training Summary Pane
Exchanges View has a Tx Training Summary pane. This pane is present only when the selected
ports contain transmitter training summary events. If selected ports contain both regular exchanges
and transmitter training summary events, two tabs are displayed, one for exchanges and one for
transmitter training summary events.
Figure 144: Tx Training Summary Pane

Navigating in Exchanges View

Click an exchange, wire event, or PDU to select it. Use the +/– icon for an exchange to collapse/
expand it.
Whenever an exchange, wire event, or PDU is clicked in
the
Details
320
.
pane shows the details just as it does whenever an event is selected in the event grid.
Using the Exchanges View Pane
Exchanges View
, the
Inspector
Xgig Analyzer User's Guide
tab of