Alcatel-Lucent 7710 SR Configuration Manual page 329

Service router os basic system
Hide thumbs Also See for 7710 SR:
Table of Contents

Advertisement

ref-order
Syntax
ref-order first second [third]
no ref-order
Context
config>system>sync-if-timing
Description
The synchronous equipment timing subsystem can lock to three different timing reference inputs,
those specified in the ref1 and ref2 command configuration. This command organizes the priority
order of the timing references.
If a reference source is disabled, then the clock from the next reference source as defined by ref-
order is used. If the reference sources are disabled, then clocking is derived from a local oscillator.
Note that if a sync-if-timing reference is linked to a source port that is operationally down, the port
will no longer be qualified as a valid reference.
The no form of the command resets the reference order to the default values.
Default
ref1 ref2
Parameters
first — Specifies the first timing reference to use in the reference order sequence.
second — Specifies the second timing reference to use in the reference order sequence.
third — Specifies the third timing reference to use in the reference order sequence.
ref1
Syntax
ref1
Context
config>system>sync-if-timing
Description
This command enables the context to configure parameters for the first timing reference.
Parameters
source-port — Configure the source port for the first timing reference.
ref2
Syntax
ref2
Context
config>system>sync-if-timing
Description
This command enables the context to configure parameters for the second timing reference.
7710 SR OS Basic System Configuration Guide
Values
ref1, ref2
Values
ref1, ref2
Values
ref1, ref2
Values
port-id
slot/mda/port
System Management
Page 329

Advertisement

Table of Contents
loading

Table of Contents