Time of Day

Time of Day (TOD) suites are useful when configuring many types of time-based policies or when
a large number of subscribers or SAPs require the same type of TOD changes. The TOD suite may
be configured while using specific ingress or egress ACLs or QoS policies, and is an enhancement
of the ingress and egress CLI trees.
SAPs
If a TOD Suite is assigned to a SAP, statistics collection are not collected for that SAP and
scheduler overrides cannot be collected on the SAP. If the SAP has an egress aggregate rate limit
configured, an egress scheduler policy assignment cannot be applied. When an item is configured
both on SAP level and in the TOD suite assigned to the SAP, the TOD-suite defined value takes
precedence. If a SAP belongs to an IES Interface, TOD Suites are allowed only with generic
interfaces (no subscriber, group, redundant, etc.). A policy or filter assignment configured directly
on a SAP has a lower priority than any assignment in a TOD Suite. Hence, it is possible that a new
direct configuration has no immediate effect. If the configuration is made by CLI, a warning is
given.
Multiservice Site
When applying a TOD Suite to a multi-service-site, only the scheduler policy assignment is active.
If the multi-service-site has an egress aggregate rate limit configured, any egress scheduler policy
assignment cannot be applied. While a TOD Suite is assigned to a multi-service-site, it is not
possible to configure a scheduler to override it.