Common Configuration Tasks

Configuring Power Supply Parameters

By default, 7710 SR-Series routers are configured as DC-input devices. Traps and alarms are
automatically sent if DC power supplies are installed in the power supply slots. In order to
generate traps and alarms when AC power supplies are installed in 7710 SR-Series models (except
the 7710 SR-c4) the
Configuring an existing power supply to none prior to powering off the unit will prevent an alarm
from being generated.
There are three power supply positions on the 7710 SR-c4 and two power supply positions on the
7710 SR-c12; power supply 3 is valid on the 7710 SR-c4 only.
See the 7710 SR-Series Installation Guides for instructions to install power supplies.
Use the CLI syntax displayed below to modify power supply parameters.
CLI Syntax: config>system
Example
The following example displays the
A:ALA-12>config>system# info
-----------------------------------------------------------------
..
Page 248
power-supply
power-supply {1|2|3} {dc|ac {single|multiple}|none}
:
config>system# power-supply 1 dc
config>system# power-supply 2 dc
name "ALA-12"
contact "Fred Information Technology"
location "Bldg.1-floor 2-Room 201"
clli-code "abcdefg1234"
coordinates "N 45 58 23, W 34 56 12"
power-supply 1 dc
power-supply 2 dc
name "ALA-12"
ccm 1
exit
sync-if-timing
begin
ref1
shutdown
exit
ref2
shutdown
exit
commit
exit
snmp
exit
login-control
idle-timeout 1440
7710 SR OS Basic System Configuration Guide
command must be modified.
command configuration:
power-supply