Control And Status Word 2 - Siemens SINAMICS G120D Original Instructions Manual

Cu250d-2 series
Hide thumbs Also See for SINAMICS G120D:
Table of Contents

Advertisement

7.4.1.3

Control and status word 2

Control word 2 (STW2)
Table 7- 4
Control word 2 and interconnection in the converter
Bit
Meaning
0
Drive data set selection DDS, bit 0
1
Drive data set selection DDS, bit 1
1 to 6
Reserved
7
1 = Parking axis selection
8
1 = Travel to fixed stop
9 to 15
Reserved
Status word 2 (ZSW2)
Table 7- 5
Control word 2 and interconnection in the converter
Bit
Meaning
0
1 = Drive data set DDS effective, bit 0
1
1 = Drive data set DDS effective, bit 1
2 to 4
Reserved
5
1 = Alarm class bit 0
6
1 = Alarm class bit 1
7
1 = Parking axis active
8
1 = Travel to fixed stop
9
Reserved
10
1 = Pulses enabled
11 to 15
Reserved
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
7.4 PROFIdrive profile for PROFIBUS and PROFINET
Comments
Description
---
Only for internal diagnostics when using a
SIMOTION control.
---
---
---
Motor switched on
---
Configuring the fieldbus
Interconnection
Telegram 9
Telegrams
110, 111
p0820[0] =
p0820[0] =
r2092.0
r2093.0
p0821[0] =
p0821[0] =
r2092.1
r2093.1
p0897 =
p0897 =
r2092.7
r2093.7
p1545[0] =
p1545[0] =
r2092.8
r2093.8
Interconnection
p2081[0] =
r0051.0
p2081[1] =
r0051.1
p2081[5] =
r2139.11
p2081[6] =
r2139.12
p2081[7] =
r0896.0
p2081[8] =
r1406.8
p2081[10] =
r0899.11
p2081[11] =
r0835.0