Setting functions
8.6 Basic positioner and position control
Parameter
p2598
p2599
p2507
184
Meaning
Reference point coordinate, signal source
Reference point coordinate value
Absolute encoder adjustment status
0
Error has occurred in the adjustment
1
Absolute encoder was not adjusted
2
Absolute encoder was not adjusted and encoder adjustment was initiated
3
Absolute encoder adjusted
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA