Configuring the fieldbus
7.4 PROFIdrive profile for PROFIBUS and PROFINET
7.4
PROFIdrive profile for PROFIBUS and PROFINET
7.4.1
Cyclic communication
7.4.1.1
Positioner: Cyclic communication
The send and receive telegrams of the inverter for cyclic communication are structured as
follows:
Figure 7-1
Telegrams for cyclic communication - Position control
Table 7- 1
Explanation of the abbreviations
Abbreviation
Explanation
STW
Control word
ZSW
Status word
SATZANW
Selects the traversing block
AKTSATZ
Currently selected traversing block
MDI_TARPOS
Position setpoint for direct setpoint input (MDI)
XIST_A
Actual position value (32 bits)
OVERRIDE
Speed setpoint
94
See Control and status word 1 (Page 97)
See Control and status word 2 (Page 99)
See Control word block selection
(Page 106)
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA