Configuring the fieldbus
7.4 PROFIdrive profile for PROFIBUS and PROFINET
7.4.1.7

Control word block selection

Block selection
Table 7- 12
Block selection and interconnection in the converter
Bit
Meaning
0
Block selection, bit 0
1
Block selection, bit 1
2
Block selection, bit 2
3
Block selection, bit 3
4...14
Reserved
15
0 = Deactivate MDI
1 = Activate MDI
Actual traversing block
Table 7- 13
Feedback signal of the actual traversing block
Bit
Meaning
0
Actual traversing block, bit 0
1
Actual traversing block, bit 1
2
Actual traversing block, bit 2
3
Actual traversing block, bit 3
4...14
Reserved
15
0 = MDI active
1 = MDI not active
106
Comments
Example for selecting
traversing block number 5:
Switching from traversing blocks to direct setpoint
input.
Comments
---
---
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
P No.
p2625 = r2091.0
p2626 = r2091.1
p2627 = r2091.2
p2628 = r2091.3
p2647 = r2091.15
P No.
p2081[0] = r2670.0
p2081[1] = r2670.1
p2081[2] = r2670.2
p2081[3] = r2670.3
p2081[15] = r2670.15
Converter with control units CU250D-2