12.2

Performance ratings Power Module

SINAMICS G120 D performance ratings
Table 12- 2
Feature
Line voltage & power
ranges
Line specification
Output voltage
Input frequency
Output frequency
cos φ
Inverter efficiency
Overload capability (HO)
Inrush current
Pulse frequency
Electromagnetic
compatibility
Protection level
Temperature range
Storage temperature
Humidity
Operational altitude
Protection features
Standards
CE mark
EM Brake
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
Power Module performance ratings
Specification
3 AC 380 V ... 500 V ± 10 %
High Overload: 0.75 kW ... 7.5 kW (1.0 hp ... 10.0 hp)
Relative short-circuit voltage of a transformer u
The specification only refers to the total instantaneous regenerative
feedback, however not to the total connected power of all of the power
modules connected to the same transformer.
Further information: FAQ
(http://support.automation.siemens.com/WW/view/en/34189181).
3 AC 0 V ... line volage × 0.87 (max.)
47 Hz ... 63 Hz
0 Hz ... 240 Hz
0.95
95 % ... 97 %
2 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds
Less than rated input current
4 kHz (standard); 4 kHz ... 16 kHz (in 2 kHz steps)
Internal Class A filters according to EN 55011
IP65 (when Power Module and Control Unit is fully assembled)
Standard CU: -10 °C ... +40 °C (14 °F ... 104 °F) - High Overload (HO)
Fail-Safe CU: 0 °C ... +40 °C (32 °F ... 104 °F) - High Overload (HO)
-40 °C ... +70 °C (-40 °F ... 158 °F)
< 95% RH - non-condensing
Up to 1000 m (3280 ft) above sea level without derating
Undervoltage, Overvoltage, Overload, Ground faults, Short circuit, Stall
prevention, Motor blocking protection, Motor overtemperature, Power
Module overtemperature, Parameter interlock
UL, cUL, CE, C-tick
Conformity with EC Low Voltage Directive 73/23/EEC and filtered
versions also Electromagnetic Compatibility Directive 89/336/EEC
180 V DC (400 V half-wave rectified) 1 A maximum
12.2 Performance ratings Power Module
≤ 1%
k
Technical data