Alarms, faults and system messages
11.6 List of alarms and faults
Number
Cause
A32442
Battery voltage pre-alarm
F32905
Parameterizing error
A32915
Configuration error
For further information, please refer to the List Manual.
324
Remedy
Replace the battery in the encoder.
Check whether the connected encoder type matches the encoder that
has been parameterized.
Correct the parameter specified by the fault value (r0949) and p0187.
When the fine resolution Gx_XIST2 is configured, the encoder identifies a
maximum possible absolute position actual value (r0483) that can no
longer be represented within 32 bits. Remedy: Check the encoder data.
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA