The higher-level controller triggers the safety functions in the inverter via the control word.
The inverter uses the status word to report the status of the safety functions to the controller.
The section Selecting the commissioning method (Page 70) contains information to help you
decide whether you must operate your inverter with "Basic Safety" or "Extended Safety".
3.3.3
Control word 0 and status word 0 (Basic Safety)
Table 3- 6
Bit
0
1 ... 6
7
8 ... 15
Table 3- 7
Bit
0
1 ... 6
7
8 ... 15
Safety Integrated Function Manual, SINAMICS G120
Function Manual, 07/2010, FW 4.3.2, A5E03052391B AA
Control word 0 (bit 0 ... 15)
Meaning
STO
Reserved
Internal event ack
Reserved
Status word 0 (bit 0 ... 15)
Meaning
Power removed
Reserved
Internal Event
Reserved
Comment
1
STO deselection
0
STO selection
Assign the value 0 to the reserved bits.
1
Acknowledge signal change 1 → 0
0
No acknowledgement
Assign the value 0 to the reserved bits.
Comment
1
The motor torque has been switched off safely.
0
The motor torque has not yet been switched off
safely.
1
Operation OK
0
The inverter has detected a major fault and
responded accordingly, e.g. with a STOP A
Activation
3.3 Activation via PROFIsafe
61