Number
Cause
F30036
Overtemperature, inside area
F30037
Rectifier overtemperature
A30049
Internal fan defective
F30059
Internal fan defective
A30502
DC link overvoltage
A30920
Temperature sensor fault
F31100
Zero mark distance error
F31101
Zero mark failed
F31118
Speed difference outside tolerance For an HTL/TTL encoder, the speed difference has exceeded the value in
A31418
Speed difference per sampling rate
exceeded
F31905
Parameterizing error
A31915
Configuration error
F32110
Serial communications error
F32111
Absolute encoder internal error
F32112
A32410
Serial communication
A32411
Absolute encoder outputs alarms
A32412
Error bit set in the serial protocol
Converter with control units CU250D-2
Operating Instructions, 04/2014, FW V4.7, A5E34261542B AA
Remedy
Check the fan filter elements.
Check whether the ambient temperature is in the permissible range.
See F30035 and, in addition:
Check the motor load.
Check the line phases
Check the internal fan and if required replace.
Check the internal fan and if required replace.
Check the unit supply voltage (p0210).
Check the dimensioning of the line reactor.
Check that the sensor is connected correctly.
The measured zero mark distance does not correspond to the
parameterized zero mark distance. Remedy:
Check that the encoder cables are routed in compliance with EMC.
Check the cable connections.
Check the encoder type (encoder with equidistant zero marks).
Adapt the parameters for the distance between zero marks (p0424,
p0425).
For a signal output above a speed threshold, reduce the filter time
(p0438).
p0492 over several sampling cycles.
Check tachometer feeder cable for interruptions.
Check the grounding of the tachometer shielding.
Increase the maximum speed difference per sampling cycle (p0492).
Check whether the connected encoder type matches the encoder that
has been parameterized.
When the fine resolution Gx_XIST2 is configured, the encoder identifies a
maximum possible absolute position actual value (r0483) that can no
longer be represented within 32 bits. Remedy: Check the encoder data.
The transfer of the serial communication protocol between the encoder
and converter is faulty. Remedy: Check the hardware and the associated
settings in the converter.
Check the power supply of the encoder.
Replace the encoder.
Check that the encoder cables are routed in compliance with EMC.
Check the cable connections.
Replace the encoder.
Replace the encoder.
Carry out a power on reset (power off/on) for all components.
Check that the encoder cables are routed in compliance with EMC.
Check the plug connections.
Replace the encoder
Alarms, faults and system messages
11.6 List of alarms and faults