CHAPTER 6: IEC 60870-5-104 COMMUNICATION
Cause of transmission
One Octet
 Two Octets (with originator address). Originator address is set to zero if not used.
Maximum Length of APDU: 253 (the maximum length may be reduced by the system)
Selection of standard ASDUs
For the following lists, the boxes indicate the following:
 – used in standard direction
 – not used
– cannot be selected in IEC 60870-5-104 standard
Process information in monitor direction
<1> := Single-point information
<2> := Single-point information with time tag
<3> := Double-point information
<4> := Double-point information with time tag
<5> := Step position information
<6> := Step position information with time tag
<7> := Bitstring of 32 bits
<8> := Bitstring of 32 bits with time tag
<9> := Measured value, normalized value
<10> := Measured value, normalized value with time tag
<11> := Measured value, scaled value
<12> := Measured value, scaled value with time tag
<13> := Measured value, short floating point value
<14> := Measured value, short floating point value with time tag
<15> := Integrated totals
<16> := Integrated totals with time tag
<17> := Event of protection equipment with time tag
<18> := Packed start events of protection equipment with time tag
<19> := Packed output circuit information of protection equipment with time tag
<20> := Packed single-point information with status change detection
<21> := Measured value, normalized value without quantity descriptor
<30> := Single-point information with time tag CP56Time2a
<31> := Double-point information with time tag CP56Time2a
<32> := Step position information with time tag CP56Time2a
<33> := Bitstring of 32 bits with time tag CP56Time2a
<34> := Measured value, normalized value with time tag CP56Time2a
<35> := Measured value, scaled value with time tag CP56Time2a
<36> := Measured value, short floating point value with time tag CP56Time2a
<37> := Integrated totals with time tag CP56Time2a
<38> := Event of protection equipment with time tag CP56Time2a
<39> := Packed start events of protection equipment with time tag CP56Time2a
<40> := Packed output circuit information of protection equipment with time tag CP56Time2a M_EP_TF_1
UR FAMILY – COMMUNICATIONS GUIDE
INTEROPERABILITY DOCUMENT
M_SP_NA_1
M_SP_TA_1
M_DP_NA_1
M_DP_TA_1
M_ST_NA_1
M_ST_TA_1
M_BO_NA_1
M_BO_TA_1
M_ME_NA_1
M_NE_TA_1
M_ME_NB_1
M_NE_TB_1
M_ME_NC_1
M_NE_TC_1
M_IT_NA_1
M_IT_TA_1
M_EP_TA_1
M_EP_TB_1
M_EP_TC_1
M_SP_NA_1
M_ME_ND_1
M_SP_TB_1
M_DP_TB_1
M_ST_TB_1
M_BO_TB_1
M_ME_TD_1
M_ME_TE_1
M_ME_TF_1
M_IT_TB_1
M_EP_TD_1
M_EP_TE_1
6-3
6