MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
3.5.6.7 Digital counters (DigCnt)
This element is instantiated in the following products: B30, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60.
Table 3-209: Digital counter data objects
LNName: DigCntFCNT#
data obj. data attribute
HiLim
stVal
EqLim
stVal
3
LoLim
stVal
CntVal
actVal
frVal
frTm
units.SIUnit
units.multiplier
pulsQty
frEna
strTm
frPd
frRs
InRef1
setSrcRef
setSrcCB
InRef2
setSrcRef
setSrcCB
InRef3
setSrcRef
setSrcCB
InRef4
setSrcRef
setSrcCB
InRef5
setSrcRef
setSrcCB
InRef6
setSrcRef
setSrcCB
BlkRef1
setSrcRef
3-198
LDevice inst: Gen
UR element: Digital Counters #
Type
FC UR Name
SPS
BOOLEAN
ST
Counter #(CNT#) HI
SPS
BOOLEAN
ST
Counter #(CNT#) EQL
SPS
BOOLEAN
ST
Counter #(CNT#) LO
BCR
INT64
ST
actual value of Counter #
ACCUM
INT64
ST
actual value of Counter #
FROZEN (count)
TimeStamp
ST
actual value of Counter #
FROZEN (date/time) combined
with Counter # MICROS
(fractional seconds)
ENUMERATED
COUNTER # UNITS
ENUMERATED
COUNTER # UNITS
FLOAT32
CF
BOOLEAN
CF
TimeStamp
CF
INT32
CF
BOOLEAN
CF
ORG
ObjectReference SP
COUNTER # UP setting
ObjectReference SP
ORG
ObjectReference SP
COUNTER # DOWN setting
ObjectReference SP
ORG
ObjectReference SP
CNT# SET TO PRESET setting
ObjectReference SP
ORG
ObjectReference SP
COUNTER # RESET setting
ObjectReference SP
ORG
ObjectReference SP
COUNTER # FREEZE/RESET
setting
ObjectReference SP
ORG
ObjectReference SP
COUNTER # FREEZE/COUNT
setting
ObjectReference SP
ORG
ObjectReference SP
COUNTER # BLOCK setting
CHAPTER 3: IEC 61850 COMMUNICATION
Description
Counter #(CNT#) HI, which indicates the
number of pulses counted is above the
set number.
Counter #(CNT#) EQL operand, which
indicates the number of pulses counted is
equal to the set number
Counter #(CNT#) LO operand, which
indicates the number of pulses counted is
below the set number.
Counter # ACCUM, which indicates the
accumulated number of pulses
1
0
0
COUNTER # UP setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
COUNTER # DOWN setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
CNT# SET TO PRESET setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
COUNTER # RESET setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
COUNTER # FREEZE/RESET setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
COUNTER # FREEZE/COUNT setting.
reference to the data attribute to input
source GoCB of input if via GOOSE
COUNTER # BLOCK setting.
reference to the data attribute to input
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C
R/C
R
R/C