GE B30 Communications Manual page 102

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
6179
"
617A
"
617B
"
617C
"
617D
"
617E
2
Transformer Thermal Inputs (Read/Write Command)
G30, T35, T60
6180
Transformer Percent Differential (Read/Write Grouped Setting)
G30, T35, T60
61C0
"
61C1
"
61C2
"
61C3
"
61C4
"
61C5
"
61C6
"
61C7
"
61C8
"
61C9
"
61CA
"
61CC
"
61CD
"
61CE
Transformer Instantaneous Differential (Read/Write Grouped Setting)
T35, T60
61DA
"
61DB
"
61DC
"
61DE
"
61DF
Autoreclose (Read/Write Setting) (1, 3, 4, or 6 Modules)
D30, F35, F60,
6200
L30
"
6201
"
6203
"
6205
"
6206
"
6208
"
620A
"
620B
"
620C
"
620E
"
6210
"
6211
"
6212
2-82
July Average Ambient Temperature
August Average Ambient Temperature
September Average Ambient Temperature -60 to 60
October Average Ambient Temperature
November Average Ambient Temperature
December Average Ambient Temperature
Transformer Loss of Life Clear Command
Percent Differential Function
Percent Differential Pickup
Percent Differential Slope 1
Percent Differential Break 1
Percent Differential Break 2
Percent Differential Slope 2
Inrush Inhibit Function
Inrush Inhibit Level
Overexcitation Inhibit Function
Overexcitation Inhibit Level
Percent Differential Block
Percent Differential Target
Percent Differential Events
Transformer Inrush Inhibit Mode
Inst Differential Function
Inst Differential Pickup
Inst Differential Block
Inst Differential Target
Inst Differential Events
Autoreclose 1 Function
Autoreclose 1 Initiate
Autoreclose 1 Block
Autoreclose 1 Max Number of Shots
Autoreclose 1 Manual Close
Autoreclose 1 Manual Reset from LO
Autoreclose 1 Reset Lockout if Breaker
Closed
Autoreclose 1 Reset Lockout On Manual
Close
Autoreclose 1 Breaker Closed
Autoreclose 1 Breaker Open
Autoreclose 1 Block Time Upon Manual
Close
Autoreclose 1 Dead Time Shot 1
Autoreclose 1 Dead Time Shot 2
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
-60 to 60
°C
1
-60 to 60
°C
1
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
-60 to 60
°C
1
0 to 1
---
1
0 to 1
---
1
0.05 to 1
pu
0.001 F001
15 to 100
%
1
1 to 2
pu
0.001 F001
2 to 30
pu
0.001 F001
50 to 100
%
1
0 to 2
---
1
1 to 40
%f
0.1
o
0 to 1
---
1
1 to 40
%f
0.1
o
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 3
---
1
0 to 1
---
1
2 to 30
pu
0.001 F001
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
1 to 4
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 655.35
s
0.01
0 to 655.35
s
0.01
0 to 655.35
s
0.01
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F002
30
F002
30
F002
20
F002
10
F002
10
F002
-10
F126
0 (No)
F102
0 (Disabled)
100
F001
25
2000
8000
F001
90
F168
1 (Adapt.
2nd)
F001
200
F169
0 (Disabled)
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F189
0 (Per phase)
F102
0 (Disabled)
8000
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
F300
0
F300
0
F001
1
F300
0
F300
0
F108
0 (Off)
F108
0 (Off)
F300
0
F300
0
F001
1000
F001
100
F001
200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents