MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Data object
CDC
name
VolRem1
CMV
VolRem2
CMV
VoltMntr
SPS
VoltsInd
SPS
VOp
MV
VRst
MV
VSigLos
SPS
3
Watt
MV
WDmd
MV
WMaxDmdDt
MV
Year
INS
Z1Chr1
SPS
Zero
MV
Zn1Extend
SPS
Zn2Tr
SPS

3.5.8 Enumerations

3.5.8.1 Standard enumerations
EnumType id and the EnumType content of standard enumerations from IEC 61850 7-4 match those in the tissues
standard.
EnumType id and EnumType content of standard enumerations from IEC 61850 7-3 match those in IEC 61850 7-3:Annex D.
3.5.8.2 GE extended enumerations
For extended enumerations, EnumType id begins with the string "GE_Digital_Energy_UR_", followed by descriptive text,
followed by "Kind". The following is a sample excerpt of the extended Enumerations from a firmware-generated UR.ICD
file.
<EnumType id="GE_Digital_Energy_UR_HiZStKind">
<EnumVal ord="0">Normal</EnumVal>
<EnumVal ord="1">Coordination Timeout</EnumVal>
<EnumVal ord="2">Armed</EnumVal>
<EnumVal ord="5">Arcing</EnumVal>
<EnumVal ord="9">Downed Conductor actual values</EnumVal>
</EnumType>
<EnumType id="GE_Digital_Energy_UR_TriggerKind">
<EnumVal ord="0">None</EnumVal>
3-224
Semantics
Composite Voltage at the Remote Terminal 1, from Channel 1.
Term 1 Vcomp phasor, in primary volts.
Composite Voltage at the Remote Terminal 2, from Channel 2
Voltage Monitor.
The VOLTAGE MONITOR operand.
An LED.
The LED VOLTAGE operand.
NEUTRAL VOLTAGE UNBALANCE # Vop, in pu
NEUTRAL VOLTAGE UNBALANCE # Vres, in pu
Indicates source has lost voltage signal.
The SRC1 VT FUSE FAIL VOL LOSS operand.
Real power in a non-three-phase circuit. In this case it is the average of 3Io times
(phase shifted 3Vo), which is not exactly real power.
Power demand in Watts.
SRC 1 DMD W, in primary watt.
Max real power demand in Watt with associated date/time stamp. The ClcMth
cannot be used for MAX, as the time stamp definition of IEC 61850 is different
from UR.
SRC 1 DMD W, in primary watt, with associated date, SRC 1 DMD W DATE.
Represents the year (from 1970 onwards). The Year actual value.
Positive-sequence impedance is within the configured characteristic. This Data
Object is used by power swing detection element for outer characteristic.
The POWER SWING INNER operand.
The POWER SWING MIDDLE operand.
The POWER SWING OUTER operand.
Analog 0 fixed operand.
FlexAnalog fixed operand Off.
The zone 1 distance function must be set to the extended overreach value.
The AR ZONE 1 EXTENT operand.
Operated from overreaching zone 2 when reclosing the line.
The LINE PICKUP RCL TRIP operand.
CHAPTER 3: IEC 61850 COMMUNICATION
Used in logical nodes...
VCompMMXU
VCompMMXU
LPHD
LEDsIHMI
NuVUnPTOV
NuVUnPTOV
VtffGAPC
WattPSDE
DmdMtrMMTR
DmdMtrMMTR
TmDayGAPC
PwrSwgRPSB
Master/LLN0
Rec13pRREC
LinPkpPIOC