GE B30 Communications Manual page 303

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

CHAPTER 3: IEC 61850 COMMUNICATION
LNName: LinDfPDIF1
data obj. data attribute
Type
phsθ
CMV
phsθ.instCVal
Vector
phsθ.instCVal.mag
FLOAT32
.f
phsθ.instCVal.ang
FLOAT32
.f
phsθ.cVal
Vector
phsθ.cVal.mag.f
FLOAT32
phsθ.cVal.ang.f
FLOAT32
phsθ.units
Unit
phsθ.units.SIUnit ENUMERATED
phsθ.units
ENUMERATED
.multiplier
phsθ.db
INT32U
phsθ.dbAng
INT32U
phsθ.zeroDb
INT32U
neut
CMV
neut.instCVal
Vector
neut.instCVal.mag
FLOAT32
.f
neut.instCVal.ang
FLOAT32
.f
neut.cVal
Vector
neut.cVal.mag.f
FLOAT32
neut.cVal.ang.f
FLOAT32
neut.units
Unit
neut.units.SIUnit ENUMERATED
neut.units
ENUMERATED
.multiplier
neut.db
INT32U
neut.dbAng
INT32U
neut.zeroDb
INT32U
angRef
ENUMERATED
RstA
WYE
phsθ
CMV
phsθ.instCVal
Vector
phsθ.instCVal.mag
FLOAT32
.f
phsθ.cVal
Vector
phsθ.cVal.mag.f
FLOAT32
phsθ.units
Unit
phsθ.units.SIUnit ENUMERATED
phsθ.units
ENUMERATED
.multiplier
phsθ.db
INT32U
phsθ.zeroDb
INT32U
neut
CMV
neut.instCVal
Vector
neut.instCVal.mag
FLOAT32
.f
neut.cVal
Vector
UR FAMILY – COMMUNICATIONS GUIDE
LDevice inst: Prot
UR element: Line Differential element (ANSI 87L) phase and general
functions
FC UR Name
MX
Iθ DIFF. CURRENT magnitude, in
primary amps
Iθ DIFF. CU
MX
Iθ DIFF. CURRENT magnitude, in
primary amps, with deadband
Iθ DIFF. CU
CF
CF
LinDfPDIF1.DifAClc.phsθ.db
CF
LinDfPDIF1.DifAClc.phsθ.dbAng
CF
CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
MX
IG DIFF. CURRENT magnitude, in
primary amps
IG DIFF. CU
MX
IG DIFF. CURRENT magnitude, in
primary amps, with deadband
IG DIFF. CU
CF
CF
LinDfPDIF1.DifAClc.neut.db
CF
LinDfPDIF1.DifAClc.neut.dbAng
CF
CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
CF
MX
Iθ RESTR. CURRENT magnitude,
in primary amps
MX
Iθ RESTR. CURRENT magnitude,
in primary amps, with deadband
CF
CF
LinDfPDIF1.DifAClc.phsθ.db
CF
CURRENT CUT-OFF LEVEL setting
multiplied by 100000/46.
MX
IG RESTR. CURRENT magnitude,
in primary amps
MX
MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
Description
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
5, the code for amps
0, the code for a multiplier of 1
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
Restraint currents
5, the code for amps
0, the code for a multiplier of 1
R/W/C
R
R
R
R
R
R
R
3
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R
R
R
R
R
3-65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents