MEMORY MAP
Products
Address Register name
"
B307
"
B308
"
B309
"
B30A
2
"
B30B
"
B30C
"
B30E
"
B30F
"
B310
"
B311
"
B312
F35
B324
"
B336
Wattmetric Ground Fault Actual Values (Read Only) (2 or 4 Modules)
D30, D60, F35,
B360
F60, L60, L90
"
B362
F35
B364
"
B366
IEC 61850 GGIO1 Configuration Settings (Read/Write Setting)
All
B400
"
B402
Contact Input Thresholds (Read/Write Setting)
All
B982
Virtual Inputs (Read/Write Setting) (64 Modules)
All
B9B2
"
B9B3
"
B9BD
"
B9BE
"
B9BF
"
B9C2
"
B9D2
"
B9E2
"
B9F2
"
BA02
"
BA12
"
BA22
"
BA32
"
BA42
"
BA52
"
BA62
"
BA72
"
BA82
"
BA92
2-162
Wattmetric Ground Fault 1 Power Pickup
Wattmetric Ground Fault 1 ECA
Wattmetric Ground Fault 1 Power Pickup
Delay
Wattmetric Ground Fault 1 Curve
Wattmetric Ground Fault 1 Multiplier
Wattmetric Ground Fault 1 Block
Wattmetric Ground Fault 1 Target
Wattmetric Ground Fault 1 Events
Wattmetric Ground Fault 1 Reference
Power
Wattmetric Ground Fault 1 Reserved
...Repeated for Wattmetric Ground Fault 2
...Repeated for Wattmetric Ground Fault 3
...Repeated for Wattmetric Ground Fault 4
Wattmetric Ground Fault 1 Operating
Power
...Repeated for Wattmetric Ground Fault 2
...Repeated for Wattmetric Ground Fault 3
...Repeated for Wattmetric Ground Fault 4
Number of Status Indications in GGIO1
IEC 61850 GGIO1 Indication FlexLogic
operands (128 items)
Contact Input x Threshold (48 items)
Virtual Input 1 Function
Virtual Input 1 Name
Virtual Input 1 Programmed Type
Virtual Input 1 Events
Reserved (3 items)
...Repeated for Virtual Input 2
...Repeated for Virtual Input 3
...Repeated for Virtual Input 4
...Repeated for Virtual Input 5
...Repeated for Virtual Input 6
...Repeated for Virtual Input 7
...Repeated for Virtual Input 8
...Repeated for Virtual Input 9
...Repeated for Virtual Input 10
...Repeated for Virtual Input 11
...Repeated for Virtual Input 12
...Repeated for Virtual Input 13
...Repeated for Virtual Input 14
...Repeated for Virtual Input 15
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0.001 to 1.2
pu
0.001 F001
0 to 360
° Lag
1
0 to 600
s
0.01
0 to 5
---
1
0.01 to 2
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0.001 to 1.2
pu
0.001 F001
0 to 1
---
1
0 to 999999.999
W
0.001 F060
8 to 128
---
8
0 to 4294967295
---
1
0 to 3
---
1
0 to 1
---
1
---
---
---
0 to 1
---
1
0 to 1
---
1
---
---
---
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
100
F001
0
F001
20
F236
0 (Definite
Time)
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
500
F001
0
0
F001
8
F300
0
F128
2 (84 Vdc)
F102
0 (Disabled)
F636
"Virt Ip 1"
F127
0 (Latched)
F102
0 (Disabled)
F001
0