GE B30 Communications Manual page 202

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
EB13
"
EB20
"
EB2D
Phasor Measurement Unit df/dt Trigger (Read/Write Setting) (1, 2, or 6 Modules)
C60, D60, F60,
EB3A
G60, L30, L90,
2
N60, T60
"
EB3B
"
EB3C
"
EB3D
"
EB3E
"
EB3F
"
EB45
"
EB46
C60, N60
EB47
N60
EB54
"
EB61
"
EB6E
"
EB7B
Phasor Measurement Unit Power Trigger (Read/Write Setting) (1, 2, or 6 Modules)
C60, D60, F60,
EB88
G60, L30, L90,
N60, T60
"
EB89
"
EB8A
"
EB8B
"
EB8C
"
EB8D
"
EB8E
"
EB94
"
EB95
C60, N60
EB96
N60
EBA4
"
EBB2
"
EBC0
"
EBCE
Phasor Measurement Unit Calibration (Read/Write Setting) (1, 2, or 6 Modules)
C60, D60, F60,
EBDC
G60, L30, L90,
N60, T60
"
EBDD
"
EBDE
"
EBDF
"
EBE0
"
EBE1
"
EBE2
"
EBE3
"
EBE4
"
EBE5
2-182
...Repeated for PMU 4
...Repeated for PMU 5
...Repeated for PMU 6
PMU 1 df/dt Trigger Function
PMU 1 df/dt Trigger Raise
PMU 1 df/dt Trigger Fall
PMU 1 df/dt Trigger Pkp Time
PMU 1 df/dt Trigger Dpo Time
PMU 1 df/dt Trigger Block (3 items)
PMU 1 df/dt Trigger Target
PMU 1 df/dt Trigger Events
...Repeated for PMU 2
...Repeated for PMU 3
...Repeated for PMU 4
...Repeated for PMU 5
...Repeated for PMU 6
PMU 1 Power Trigger Function
PMU 1 Power Trigger Active
PMU 1 Power Trigger Reactive
PMU 1 Power Trigger Apparent
PMU 1 Power Trigger Pkp Time
PMU 1 Power Trigger Dpo Time
PMU 1 Power Trigger Block (3 items)
PMU 1 Power Trigger Target
PMU 1 Power Trigger Events
...Repeated for PMU 2
...Repeated for PMU 3
...Repeated for PMU 4
...Repeated for PMU 5
...Repeated for PMU 6
PMU 1 Va Calibration Angle
PMU 1 Va Calibration Magnitude
PMU 1 Vb Calibration Angle
PMU 1 Vb Calibration Magnitude
PMU 1 Vc Calibration Angle
PMU 1 Vc Calibration Magnitude
PMU 1 Vx Calibration Angle
PMU 1 Vx Calibration Magnitude
PMU 1 Ia Calibration Angle
PMU 1 Ia Calibration Magnitude
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0.1 to 15
Hz/s
0.01
0.1 to 15
Hz/s
0.01
0 to 600
seconds 0.01
0 to 600
seconds 0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0 to 1
---
1
0.25 to 3
pu
0.001 F001
0.25 to 3
pu
0.001 F001
0.25 to 3
pu
0.001 F001
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
-5 to 5
°
0.05
95 to 105
%
0.1
-5 to 5
°
0.05
95 to 105
%
0.1
-5 to 5
°
0.05
95 to 105
%
0.1
-5 to 5
°
0.05
95 to 105
%
0.1
-5 to 5
°
0.05
95 to 105
%
0.1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F001
25
F001
25
F001
10
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F102
0 (Disabled)
1250
1250
1250
F001
10
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F002
0
F002
1000
F002
0
F002
1000
F002
0
F002
1000
F002
0
F002
1000
F002
0
F002
1000