GE B30 Communications Manual page 208

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
"
T35, T60
"
C70, D30, D60, F35,
F60, L30, L60, L90,
2
T60
"
T60
D30, D60, G60, L90,
T60
G30, G60
N60
"
"
"
"
"
C70, D30, D60, F35,
F60, L30, L60, L90,
T60
"
T60
C70, D30, D60, F60,
G30, G60, L30, L60,
M60, T60
"
"
G30, G60
F60
B30
"
D30, D60, F35, F60,
L60, L90
"
F35
"
C60, D30, D60, F35,
F60, G30, G60, L30,
L60, L90, M60, T60
"
"
All except B90, C30,
T35
"
"
All except B90, C30,
N60, T35
2-188
Bit
Element
mas
k
89
Restricted Ground Fault 4
90
Restricted Ground Fault 5
91
Restricted Ground Fault 6
96
Negative Sequence Instantaneous
Overcurrent 1
97
Negative Sequence Instantaneous
Overcurrent 2
98
Negative Sequence Instantaneous
Overcurrent 3
99
Fast Distance
101 Change Phase Rotation
102 8-bit Comparator 1
103 8-bit Comparator 2
104 8-bit Comparator 3
105 8-bit Comparator 4
106 8-bit Comparator 5
107 8-bit Comparator 6
112 Negative Sequence Time Overcurrent
1
113 Negative Sequence Time Overcurrent
2
114 Negative Sequence Time Overcurrent
3
120 Negative Sequence Overvoltage 1
121 Negative Sequence Overvoltage 2
122 Negative Sequence Overvoltage 3
125 Generator Unbalance
128 High Impedance Fault Detection (Hi-Z)
133 Bus Zone 1
134 Bus Zone 2
135 Wattmetric 1
136 Wattmetric 2
137 Wattmetric 3
138 Wattmetric 4
140 Auxiliary Undervoltage 1
141 Auxiliary Undervoltage 2
142 Auxiliary Undervoltage 3
144 Phase Undervoltage 1
145 Phase Undervoltage 2
146 Phase Undervoltage 3
148 Auxiliary Overvoltage 1
CHAPTER 2: MODBUS COMMUNICATION
Products
Bit
Element
mas
k
B30, C60, C70, D60,
149 Auxiliary Overvoltage 2
F35, F60, G30, G60,
L90, M60, T60
B30, C70, F35, T60 150 Auxiliary Overvoltage 3
All except B90, C30,
151 Phase Overvoltage 1
T35
"
152 Phase Overvoltage 2
"
153 Phase Overvoltage 3
D60, L60, L90
154 Compensated Overvoltage
All except B90, C30,
156 Neutral Overvoltage 1
N60, T35
"
157 Neutral Overvoltage 2
"
158 Neutral Overvoltage 3
D30, D60, G60, L60,
160 Phase Distance Zone 1
L90, T60
"
161 Phase Distance Zone 2
"
162 Phase Distance Zone 3
D30, D60, L90 T60
163 Phase Distance Zone 4
"
164 Phase Distance Zone 5
D30, D60, L60, L90 168 Line Pickup
D30, D60, L60, L90,
172 Ground Distance Zone 1
T60
"
173 Ground Distance Zone 2
"
174 Ground Distance Zone 3
D30, D60, L90, T60 175 Ground Distance Zone 4
"
176 Ground Distance Zone 5
D30, D60, F60, L60,
180 Load Encroachment
L90, T60
F60
182 POTT3
F60
183 DCB3
D60, L90
184 DUTT
D60, L90
185 PUTT
D60, L60, L90
186 POTT
D60, L90
187 Hybrid POTT
"
188 Block Scheme
D30, D60, G60, L60,
190 Power Swing Detect
L90, N60, T60
G30, T35, T60
202 Transformer Hottest Spot
"
203 Transformer Aging Factor
"
204 Transformer Loss of Life
T35, T60
208 Transformer Instantaneous
Differential
G30, T35, T60
209 Transformer Percent Differential
G30, G60, L90, T60 210 Volt per Hertz 1
"
211 Volt per Hertz 2
C60, D60, F60, G30,
214 Sensitive Directional Power 1
G60, L90, M60,
N60, T60
"
215 Sensitive Directional Power 2
UR FAMILY – COMMUNICATIONS GUIDE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents