MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: PctDifPDIF1
data obj. data attribute
phsθ.instCVal
phsθ.instCVal.mag
.f
phsθ.instCVal.ang
.f
phsθ.cVal
phsθ.cVal.mag.f
phsθ.cVal.ang.f
phsθ.units
phsθ.units.SIUnit ENUMERATED
phsθ.units
.multiplier
phsθ.db
3
phsθ.dbAng
phsθ.zeroDb
angRef
RstA
phsθ
phsθ.instCVal
phsθ.instCVal.mag
.f
phsθ.instCVal.ang
.f
phsθ.cVal
phsθ.cVal.mag.f
phsθ.cVal.ang.f
phsθ.units
phsθ.units.SIUnit ENUMERATED
phsθ.units
.multiplier
phsθ.db
phsθ.dbAng
phsθ.zeroDb
angRef
BlkRefγ
setSrcRef
setSrcCB
3.5.2.76 Trip bus (TrBus)
This element is instantiated in all UR products (B30, B90, C30, C60, C70, D30, D60, F35, F60, G30, G60, L30, L60, L90, M60,
N60, T35, T60).
Table 3-125: Trip bus data objects
LNName: TrBusPTRC#
data obj. data attribute
Op
general
Str
general
3-110
LDevice inst: Prot
UR element: Transformer Percent Differential function
Type
FC UR Name
Vector
MX
FLOAT32
DIFF 5TH HARM Iθd magnitude,
in %
FLOAT32
DIFF 5TH HA
Vector
MX
FLOAT32
DIFF 5TH HARM Iθd magnitude,
in %, with deadband
FLOAT32
DIFF 5TH HA
Unit
CF
ENUMERATED
INT32U
CF
PctDifPDIF#.DifA5thH.phsθ.db
INT32U
CF
PctDifPDIF#.DifA5thH.phsθ.dbAn
g
INT32U
CF
ENUMERATED
CF
WYE
CMV
Vector
MX
FLOAT32
REST PHASOR Iθr magnitude, in
pu
FLOAT32
REST PHASOR
Vector
MX
FLOAT32
REST PHASOR Iθr magnitude, in
pu, with deadband
FLOAT32
REST PHASOR
Unit
CF
ENUMERATED
INT32U
CF
PctDifPDIF#.RstA.phsθ.db
INT32U
CF
PctDifPDIF#.RstA.phsθ.dbAng
INT32U
CF
ENUMERATED
CF
ORG
ObjectReference SP
PERCENT DIFF BLOCK for group
γ.
ObjectReference SP
LDevice inst: Prot
UR element: Trip Bus element #
Type
FC UR Name
ACT
BOOLEAN
ST
TRIP BUS # OP
ACD
BOOLEAN
ST
TRIP BUS # PKP
CHAPTER 3: IEC 61850 COMMUNICATION
Description
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
1, the code for dimensionless
0, the code for a multiplier of 1
0
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
Phase restraint currents
UR range -180...+180 converted to 0...360 R
UR range -180...+180 converted to 0...360 R
1, the code for dimensionless
-2, the code for a multiplier of Centi
0
See UR product manual regarding
FREQUENCY AND PHASE REFERENCE
PERCENT DIFF BLOCK for setting group γ. R
reference to the data attribute to input
source GoCB of input if via GOOSE
Description
TRIP BUS # OP operand, which becomes
On when any input is On, and the element
is not blocked
TRIP BUS # PKP operand, which indicates
Op will operate when delay expires.
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R/C
R/C
R/W/C
R
R
R
R