Sign In
Upload
Manuals
Brands
GE Manuals
Relays
B90
GE B90 Manuals
Manuals and User Guides for GE B90. We have
6
GE B90 manuals available for free PDF download: Communications Manual, Instruction Manual
GE B90 Instruction Manual (510 pages)
Low Impedance Bus Differential System
Brand:
GE
| Category:
Relays
| Size: 19.81 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Safety Symbols and Definitions
9
General Cautions and Warnings
9
For Further Assistance
10
2 Product Description
13
Description
14
Security
16
Order Codes
19
Replacement Modules
24
Signal Processing
25
UR Signal Processing
25
Specifications
27
Protection Elements
28
User-Programmable Elements
29
Monitoring
30
Metering
31
Inputs
31
Power Supply
32
Outputs
33
Communications
35
Inter-Relay Communications
36
Cybersentry Security
37
Graphical Front Panel
37
Environmental
38
Type Tests
39
Production Tests
39
Approvals
40
Maintenance
40
3 Installation
41
Unpack and Inspect
41
Panel Cutouts
42
Rear Terminal Layout
45
Wiring
47
Typical Wiring
47
Dielectric Strength
53
Control Power
53
CT and VT Modules
54
Contact Inputs and Outputs
55
RS232 Port
66
CPU Communication Ports
67
Irig-B
69
Direct Input and Output Communications
70
Description
70
Fiber: LED and ELED Transmitters
73
Fiber Laser Transmitters
73
Interface
74
RS422 Interface
78
RS422 and Fiber Interface
80
And Fiber Interface
81
IEEE C37.94 Interface
81
C37.94SM Interface
84
Activate Relay
87
Install Software
88
Enervista Communication Overview
88
System Requirements
89
Install Software
90
Add Device to Software
91
Set IP Address in UR
91
Configure Serial Connection
96
Configure Ethernet Connection
97
Configure Modem Connection
99
Automatic Discovery of UR Devices
99
Connect to the B90
100
Connect to the B90 in Enervista
100
Use Quick Connect Via the Front Panel RS232 Port
101
Use Quick Connect Via a Rear Ethernet Port
102
Set up Cybersentry and Change Default Password
103
Import Settings
103
Connect to D400 Gateway
104
Oscillography Files
104
Event Records
104
Log Files
104
Setting Files
105
4 Interfaces
107
Enervista Software Interface
107
Introduction
107
Settings Files
107
Event Viewing
108
File Support
109
Enervista Main Window
109
Protection Summary Window
110
Settings Templates
111
Secure and Lock Flexlogic Equations
115
Settings File Traceability
118
Front Panel Interface
120
Front Panel
120
Front Panel Display
122
Front Panel Navigation Keys
143
LED Indicators
145
Front Panel Labelling
149
Menu Navigation
156
Change Settings
158
View Actual Values
163
Change Passwords
164
Invalid Password Entry
166
Logic Diagrams
166
Flexlogic Design Using Engineer
167
Design Logic
169
Send File to and from Device
179
Monitor Logic
180
View Front Panel and Print Labels
181
Generate Connectivity Report
182
Preferences
182
Toolbars
186
5 Settings
193
Settings Menu
193
Overview
195
Introduction to Elements
195
Product Setup
197
B90 Function
197
Security
197
Display Properties
215
Graphical Front Panel
216
Clear Relay Records
228
Communications
229
Modbus User Map
291
Real-Time Clock
291
User-Programmable Fault Report
296
Oscillography
297
User-Programmable Leds
302
User-Programmable Self-Tests
303
Control Pushbuttons
304
User-Programmable Pushbuttons
305
Flex State Parameters
311
User-Definable Displays
312
Direct Inputs and Outputs
314
Installation
320
System Setup
321
AC Inputs
321
Power System
321
Flexcurves
322
Bus
329
Flexlogic
331
Flexlogic Operands
331
Flexlogic Rules
339
Flexlogic Evaluation
339
Flexlogic Example
340
Flexlogic Equation Editor
345
Flexlogic Timers
345
Non-Volatile Latches
345
Grouped Elements
346
Overview
346
Setting Group 1
346
Bus Differential
347
Breaker Failure (ANSI 50BF)
352
Voltage Elements
360
Current Elements
361
End Fault Protection
368
Control Elements
371
Overview
371
Trip Bus
371
Setting Groups
373
Digital Elements
374
Monitoring Elements
377
Inputs/Outputs
382
Contact Inputs
382
Virtual Inputs
384
Contact Outputs
385
Virtual Outputs
388
Resetting
388
Direct Inputs and Outputs
389
Testing
393
Test Mode Function
393
Test Mode Forcing
394
Force Contact Inputs
394
Force Contact Outputs
395
6 Actual Values
398
Front Panel
398
Status
399
Contact Inputs
399
Virtual Inputs
399
Rxgoose Boolean Inputs
400
Rxgoose DPS Inputs
400
Contact Outputs
400
Virtual Outputs
400
Rxgoose Status
401
Rxgoose Statistics
401
Flex States
402
Ethernet
402
Real Time Clock Synchronizing
402
Direct Inputs
403
Direct Devices Status
403
Remaining Connection Status
404
Parallel Redundancy Protocol (PRP)
404
Metering
405
Txgoose Status
405
Metering Conventions
405
Bus Zone
406
Currents
406
Voltages
407
Frequency
407
Rxgoose Analogs
407
Records
407
User-Programmable Fault Reports
407
Event Records
408
Oscillography
409
Product Information
410
Model Information
410
Firmware Revisions
410
7 Commands and Targets
413
Commands Menu
413
Virtual Inputs
414
Clear Records
414
Set Date and Time
414
Relay Maintenance
415
Targets Menu
416
Target Messages
417
Relay Self-Tests
417
Advertisement
GE B90 Instruction Manual (442 pages)
Low Impedance Bus Differential System
Brand:
GE
| Category:
Control Unit
| Size: 16.63 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Safety Symbols and Definitions
9
General Cautions and Warnings
9
For Further Assistance
10
2 Product Description
13
Overview
13
Security
16
Order Codes
19
Replacement Modules
24
Signal Processing
26
UR Signal Processing
26
Specifications
28
Protection Elements
28
User-Programmable Elements
29
Monitoring
31
Metering
31
Inputs
31
Power Supply
33
Outputs
33
Communications
35
Inter-Relay Communications
36
Cybersentry Security
37
Environmental
37
Type Tests
38
Production Tests
39
Approvals
39
Maintenance
39
3 Installation
41
Unpack and Inspect
41
Panel Cutouts
42
Rear Terminal Layout
44
Wiring
45
Typical Wiring
45
Dielectric Strength
51
Control Power
51
CT and VT Modules
52
Contact Inputs and Outputs
53
RS232 Faceplate Port
60
CPU Communication Ports
61
Irig-B
63
Direct Input and Output Communications
64
Description
64
Fiber: LED and ELED Transmitters
67
Fiber Laser Transmitters
67
Interface
68
RS422 Interface
72
RS422 and Fiber Interface
74
And Fiber Interface
75
IEEE C37.94 Interface
75
C37.94SM Interface
78
Activate Relay
81
Install Software
82
Enervista Communication Overview
82
System Requirements
83
Install Software
84
Add Device to Software
85
Set IP Address in UR
85
Configure Serial Connection
91
Configure Ethernet Connection
92
Configure Modem Connection
94
Automatic Discovery of UR Devices
94
Connect to the B90
95
Connect to the B90 in Enervista
95
Use Quick Connect Via the Front Panel RS232 Port
96
Use Quick Connect Via a Rear Ethernet Port
97
Set up Cybersentry and Change Default Password
97
Import Settings
98
4 Interfaces
101
Enervista Software Interface
101
Introduction
101
Settings Files
101
Event Viewing
102
File Support
103
Enervista Main Window
103
Protection Summary Window
104
Settings Templates
105
Secure and Lock Flexlogic Equations
109
Settings File Traceability
112
Front Panel Interface
115
Front Panel Display
115
Front Panel Keypad
116
Menu Navigation
116
Menu Hierarchy
116
Changing Settings
117
Faceplate
119
LED Indicators
120
Custom LED Labeling
123
Change Passwords
128
Invalid Password Entry
129
Logic Diagrams
129
Flexlogic Design and Monitoring Using Engineer
131
Design Logic
133
Send File to and from Device
143
Monitor Logic
144
View Front Panel and Print Labels
145
Generate Connectivity Report
146
Preferences
146
Toolbars
150
5 Settings
157
Settings Menu
157
Overview
159
Introduction to Elements
159
Product Setup
161
B90 Function
161
Security
161
Display Properties
179
Clear Relay Records
180
Communications
181
Modbus User Map
242
Real-Time Clock
242
User-Programmable Fault Report
246
Oscillography
247
User-Programmable Leds
249
User-Programmable Self-Tests
252
Control Pushbuttons
253
User-Programmable Pushbuttons
254
Flex State Parameters
259
User-Definable Displays
260
Direct Inputs and Outputs
262
Installation
268
System Setup
269
AC Inputs
269
Power System
269
Flexcurves
270
Bus
277
Flexlogic
279
Flexlogic Operands
279
Flexlogic Rules
286
Flexlogic Evaluation
287
Flexlogic Example
287
Flexlogic Equation Editor
292
Flexlogic Timers
292
Non-Volatile Latches
292
Grouped Elements
293
Overview
293
Setting Group 1
294
Bus Differential
294
Breaker Failure (ANSI 50BF)
299
Voltage Elements
307
Current Elements
308
End Fault Protection
315
Control Elements
318
Overview
318
Trip Bus
318
Setting Groups
320
Digital Elements
321
Monitoring Elements
324
Inputs/Outputs
329
Contact Inputs
329
Virtual Inputs
331
Contact Outputs
332
Virtual Outputs
335
Resetting
335
Direct Inputs and Outputs
336
Testing
340
Test Mode Function
340
Test Mode Forcing
340
Force Contact Inputs
341
Force Contact Outputs
341
6 Actual Values
343
Actual Values Menu
343
Front Panel
344
Status
345
Contact Inputs
345
Virtual Inputs
345
Rxgoose Boolean Inputs
346
Rxgoose DPS Inputs
346
Contact Outputs
346
Virtual Outputs
346
Rxgoose Status
347
Rxgoose Statistics
347
Flex States
347
Ethernet
348
Real Time Clock Synchronizing
348
Direct Inputs
349
Direct Devices Status
349
Remaining Connection Status
349
Parallel Redundancy Protocol (PRP)
350
Txgoose Status
350
Metering
351
Metering Conventions
351
Bus Zone
352
Currents
352
Voltages
353
Frequency
353
Rxgoose Analogs
353
User-Programmable Fault Reports
353
Event Records
354
Oscillography
355
Product Information
355
Model Information
355
Firmware Revisions
356
7 Commands and Targets
357
Commands Menu
357
Virtual Inputs
358
Clear Records
358
Set Date and Time
358
Relay Maintenance
359
Security
359
Targets Menu
360
Target Messages
360
Relay Self-Tests
361
GE B90 Instruction Manual (474 pages)
UR Series Low Impedance Bus Differential System
Brand:
GE
| Category:
Relays
| Size: 8.98 MB
Table of Contents
Table of Contents
3
1 Getting Started
11
Important Procedures
11
Cautions and Warnings
11
Inspection Procedure
12
Ur Overview
13
Introduction to the Ur
13
Hardware Architecture
14
Ur Software Architecture
15
Important Ur Concepts
15
Enervista Ur Setup Software
16
Requirements
16
Software Installation
16
Configuring the B90 for Software Access
17
Using the Quick Connect Feature
20
Connecting to the B90 Relay
26
Ur Hardware
27
Mounting and Wiring
27
Communications
27
Faceplate Display
27
Using the Relay
28
Faceplate Keypad
28
Menu Navigation
28
Menu Hierarchy
28
Relay Activation
28
Relay Passwords
29
Flexlogic™ Customization
29
Commissioning
30
2 Product Description
31
Introduction
31
Overview
31
Ordering
39
Replacement Modules
41
Specifications
42
Protection Elements
42
User-Programmable Elements
43
Monitoring
43
Metering
44
Inputs
44
Power Supply
45
Outputs
45
Communication Protocols
46
Inter-Relay Communications
47
Environmental
47
Type Tests
48
Production Tests
48
Approvals
49
Maintenance
49
3 Hardware
51
Description
51
Panel Cutout
51
Rear Terminal Layout
53
Wiring
54
Typical Wiring
54
Dielectric Strength
60
Control Power
60
Ct and Vt Modules
61
Contact Inputs and Outputs
62
Rs232 Faceplate Port
70
Cpu Communication Ports
70
Irig-B
73
Direct Input/Output Communications
75
Description
75
Fiber: Led and Eled Transmitters
77
Fiber-Laser Transmitters
77
Interface
79
Rs422 Interface
82
Rs422 and Fiber Interface
84
And Fiber Interface
84
Ieee C37.94 Interface
85
C37.94Sm Interface
89
4 Human Interfaces
93
Enervista Ur Setup Software Interface
93
Introduction
93
Creating a Site List
93
Enervista Ur Setup Overview
93
Enervista Ur Setup Main Window
95
Extended Enervista Ur Setup Features
97
Settings Templates
97
Securing and Locking Flexlogic™ Equations
101
Settings File Traceability
103
Faceplate Interface
106
Faceplate
106
Led Indicators
107
Custom Labeling of Leds
110
Display
114
Keypad
114
Menus
114
Changing Settings
116
5 Settings
117
Overview
121
Settings Menu
121
Introduction to Elements
123
Product Setup
125
B90 Function
125
Security
125
Display Properties
130
Clear Relay Records
131
Communications
132
Modbus User Map
153
Real Time Clock
153
User-Programmable Fault Report
154
Oscillography
155
User-Programmable Leds
157
User-Programmable Self Tests
161
Control Pushbuttons
161
User-Programmable Pushbuttons
163
Flex State Parameters
169
User-Definable Displays
169
Direct Inputs and Outputs
172
Installation
179
System Setup
180
Ac Inputs
180
Power System
181
Flexcurves
182
Bus
189
Flexlogic
191
Introduction to Flexlogic
191
Flexlogic™ Rules
197
Flexlogic™ Example
198
Flexlogic™ Equation Editor
202
Non-Volatile Latches
203
Overview
204
Bus Differential
205
Breaker Failure
209
Voltage Elements
217
Current Elements
218
End Fault Protection
225
Overview
228
Setting Groups
230
Digital Elements
231
Monitoring Elements
234
Contact Inputs
238
Virtual Inputs
240
Contact Outputs
241
Virtual Outputs
243
Remote Devices
244
Remote Inputs
245
Remote Double-Point Status Inputs
246
Resetting
247
Direct Inputs and Outputs
248
Iec 61850 Goose Analogs
251
Iec 61850 Goose Integers
252
Test Mode
253
Force Contact Inputs
254
Force Contact Outputs
255
Actual Values Menu
257
Contact Inputs
259
Remote Double-Point Status Inputs
260
Remote Devices
261
Ethernet
262
Direct Inputs
263
Metering Conventions
264
Currents
265
Iec 61580 Goose Analog Values
266
User-Programmable Fault Reports
267
Model Information
269
Commands Menu
271
Clear Records
272
Relay Maintenance
273
Targets Menu
274
Overview
279
Password Security Menu
280
Remote Passwords
281
Access Supervision
282
Overview
284
Modifying User Privileges
285
Bus Differential Protection
287
Dynamic Bus Replica Mechanism
288
Biased Differential Characteristic
289
Differential and Restraining Currents
290
Enhanced Security
291
Current Directional Protection
292
Ct Saturation Detection
294
Output Logic
296
Introduction
299
North Bus Zone
301
Description
302
Low Breakpoint
303
Description
304
External Faults on C-2
306
External Faults on C-4
307
Description
308
Using Setting Groups
309
Replace a Module
311
Replace Battery
313
Dispose of Battery
314
Uninstall and Clear Files and Data
317
Repairs
318
Storage
319
Disposal
320
A.1.1 Flexanalog Items
321
A.1.2 Flexinteger Items
323
B.1.1 Introduction
325
B.1.4 Modbus Rtu Crc-16 Algorithm
326
B.2.1 Supported Function Codes
328
B.2.3 Execute Operation (Function Code 05H)
329
B.2.5 Store Multiple Settings (Function Code 10H)
330
B.3.1 Obtaining Relay Files Via Modbus
331
B.4.1 Modbus Memory Map
333
B.4.2 Data Formats
377
C.1.1 Introduction
409
C.1.3 File Transfer by Iec 61850
410
C.2.1 Overview
411
C.2.6 Mmxn: Analog Measured Values
412
C.3.1 Buffered and Unbuffered Reporting
414
C.3.6 Logical Node Name Prefixes
415
C.4.1 Overview
416
C.4.5 Ethernet Mac Address for Gsse/Goose
418
C.4.6 Gsse ID and Goose ID Settings
419
C.5.1 Overview
420
C.5.2 Configuring Iec 61850 Settings
421
C.5.3 about ICD Files
422
C.5.4 Creating an ICD File with Enervista Ur Setup
426
C.5.6 Importing an Scd File with Enervista Ur Setup
429
C.6.1 Acsi Basic Conformance Statement
431
C.6.3 Acsi Services Conformance Statement
432
C.7.1 Logical Nodes Table
435
D.1.1 Interoperability Document
439
D.1.2 Iec 60870-5-104 Points
447
E.1.1 Dnp V3.00 Device Profile
449
E.1.2 Implementation Table
452
E.2.1 Binary Input Points
456
E.2.2 Binary and Control Relay Output
457
E.2.3 Analog Inputs
458
F.1.1 Revision History
459
F.2.1 Standard Abbreviations
463
F.3.1 Ge Multilin Warranty
465
Advertisement
GE B90 Instruction Manual (440 pages)
UR Series Low Impedance Bus Differential System
Brand:
GE
| Category:
Relays
| Size: 9.9 MB
Table of Contents
Table of Contents
5
1 Getting Started
13
Important Procedures
13
Cautions and Warnings
13
Inspection Checklist
13
Ur Overview
14
Introduction to the Ur
14
Hardware Architecture
15
Ur Software Architecture
16
Important Ur Concepts
16
Enervista Ur Setup Software
17
Requirements
17
Software Installation
17
Configuring the B90 for Software Access
18
Using the Quick Connect Feature
21
Connecting to the B90 Relay
27
Ur Hardware
28
Mounting and Wiring
28
Communications
28
Faceplate Display
28
Using the Relay
29
Faceplate Keypad
29
Menu Navigation
29
Menu Hierarchy
29
Relay Activation
29
Relay Passwords
30
Flexlogic™ Customization
30
Commissioning
31
2 Product Description
33
Introduction
33
Overview
33
Ordering
39
Replacement Modules
40
Specifications
42
Protection Elements
42
User-Programmable Elements
43
Monitoring
43
Metering
44
Inputs
44
Power Supply
45
Outputs
45
Communications
46
Inter-Relay Communications
47
Environmental
47
Type Tests
48
Production Tests
48
Approvals
49
Maintenance
49
3 Hardware
51
Description
51
Panel Cutout
51
Module Withdrawal and Insertion
53
Rear Terminal Layout
54
Wiring
56
Typical Wiring
56
Dielectric Strength
62
Control Power
62
Ct and Vt Modules
63
Contact Inputs and Outputs
64
Rs232 Faceplate Port
72
Cpu Communication Ports
72
Irig-B
75
Direct Input/Output Communications
77
Description
77
Fiber: Led and Eled Transmitters
79
Fiber-Laser Transmitters
79
Interface
80
Rs422 Interface
83
Rs422 and Fiber Interface
85
And Fiber Interface
85
Ieee C37.94 Interface
86
C37.94Sm Interface
89
4 Human Interfaces
93
Enervista Ur Setup Software Interface
93
Introduction
93
Creating a Site List
93
Enervista Ur Setup Overview
93
Enervista Ur Setup Main Window
95
Extended Enervista Ur Setup Features
96
Settings Templates
96
Securing and Locking Flexlogic™ Equations
100
Settings File Traceability
102
Faceplate Interface
105
Faceplate
105
Led Indicators
106
Custom Labeling of Leds
108
Display
114
Keypad
114
Menus
114
Changing Settings
115
5 Settings
115
Overview
119
Settings Menu
119
Introduction to Elements
121
Product Setup
123
B90 Function
123
Security
123
Display Properties
128
Clear Relay Records
129
Communications
130
Modbus User Map
147
Real Time Clock
148
User-Programmable Fault Report
149
Oscillography
150
User-Programmable Leds
152
User-Programmable Self Tests
155
Control Pushbuttons
155
User-Programmable Pushbuttons
157
Flex State Parameters
162
User-Definable Displays
163
Direct Inputs and Outputs
165
Installation
173
System Setup
174
Ac Inputs
174
Power System
175
Flexcurves
176
Bus
183
Bus Differential Protection
183
Flexlogic
185
Introduction to Flexlogic
185
Flexlogic™ Rules
191
Flexlogic™ Example
192
Flexlogic™ Equation Editor
196
Non-Volatile Latches
197
Overview
198
Bus Differential
199
Breaker Failure
203
Voltage Elements
211
Current Elements
212
End Fault Protection
219
Overview
222
Setting Groups
224
Digital Elements
225
Monitoring Elements
228
Contact Inputs
232
Virtual Inputs
234
Contact Outputs
235
Virtual Outputs
237
Remote Devices
238
Remote Inputs
239
Remote Double-Point Status Inputs
240
Resetting
241
Direct Inputs and Outputs
242
Iec 61850 Goose Analogs
245
Iec 61850 Goose Integers
246
Test Mode
247
Force Contact Inputs
248
Force Contact Outputs
249
Actual Values Main Menu
251
Contact Inputs
253
Remote Double-Point Status Inputs
254
Remote Devices
255
Ethernet
256
Direct Inputs
257
Metering Conventions
258
Currents
259
Iec 61580 Goose Analog Values
260
User-Programmable Fault Reports
261
Model Information
262
Virtual Inputs
263
Clear Records
264
Relay Maintenance
265
Targets Menu
266
Overview
271
Password Security Menu
272
Remote Passwords
273
Dual Permission Security Access
274
Settings Templates
276
Securing and Locking Flexlogic™ Equations
280
Settings File Traceability
282
Overview
285
Modifying User Privileges
286
Ct Ratio Matching
290
Biased Differential Characteristic
291
Differential and Restraining Currents
292
Enhanced Security
293
Current Directional Protection
294
Ct Saturation Detection
295
Output Logic
296
Introduction
299
North Bus Zone
301
Description
302
Low Breakpoint
303
Description
304
External Faults on C-2
305
External Faults on C-4
306
Description
307
Using Setting Groups
308
A.1.1 Flexanalog Items
309
A.1.2 Flexinteger Items
311
B.1.1 Introduction
313
B.1.4 Crc-16 Algorithm
314
B.2.1 Supported Function Codes
315
B.2.3 Execute Operation (Function Code 05H)
316
B.2.5 Store Multiple Settings (Function Code 10H)
317
B.3.1 Obtaining Relay Files Via Modbus
318
B.3.2 Modbus Password Operation
319
B.4.1 Modbus Memory Map
320
B.4.2 Data Formats
362
C.1.1 Introduction
377
C.2.1 Overview
378
C.2.6 Mmxn: Analog Measured Values
379
C.3.1 Buffered and Unbuffered Reporting
381
C.3.6 Logical Node Name Prefixes
382
C.4.1 Overview
383
C.4.5 Ethernet Mac Address for Gsse/Goose
385
C.4.6 Gsse ID and Goose ID Settings
386
C.5.1 Overview
387
C.5.2 Configuring Iec 61850 Settings
388
C.5.3 about ICD Files
389
C.5.4 Creating an ICD File with Enervista Ur Setup
393
C.5.6 Importing an Scd File with Enervista Ur Setup
396
C.6.1 Acsi Basic Conformance Statement
398
C.6.3 Acsi Services Conformance Statement
399
C.7.1 Logical Nodes Table
402
D.1.2 Iec 60870-5-104 Points
413
E.1.1 Dnp V3.00 Device Profile
415
E.1.2 Implementation Table
418
E.2.1 Binary Input Points
422
E.2.2 Binary and Control Relay Output
423
E.2.3 Analog Inputs
424
F.1.1 Revision History
425
F.2.1 Standard Abbreviations
430
F.3.1 Ge Multilin Warranty
432
GE B90 Communications Manual (532 pages)
Universal Relay Family
Brand:
GE
| Category:
Relays
| Size: 3.79 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
204
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
354
System Logical Device
389
Meter Logical Device
410
General (Gen) Logical Device
431
GE Namespace
447
Enumerations
462
SCL Implementation Conformance Statement (SICS)
463
PIXIT Conformance Statement
465
TICS Conformance Statement
470
SCL Logging
472
Overview of Process
472
SCL File Storage on UR
473
Generation of CID Files
473
Schema Version Used by Ur/Enervista
473
CID File Processing Steps
473
SCL Log File Format and Examples
473
Troubleshooting Log File Errors
475
G2 Implementation Model for GOOSE Configuration Via SCL
475
Introduction
475
Configuration Process
476
Configuration Process with IED Setup Tool
478
IED Capability Description (ICD) File
478
Instantiated IED Capability Description (IID) File
482
Configured IED Description (CID) File
482
Sample SCL Files
484
Annex - Optional Intermediate GOOSE Reception Objects
489
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
492
Introduction
492
Workflow
492
ICD Files
493
CID Files
494
IID Files
495
GE B90 Communications Manual (526 pages)
UR Family
Brand:
GE
| Category:
Controller
| Size: 3.78 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Products
7
Features Per Product
7
Communication Ports
20
Safety Symbols and Definitions
20
For Further Assistance
20
Modbus
21
2 Modbus Communication
21
Modbus RTU Protocol
21
Introduction
21
Configuration
21
Physical Layer
21
Data Link Layer
22
Modbus RTU CRC-16 Algorithm
23
Modbus Function Codes
24
Supported Function Codes
24
Read Actual Values or Settings (Function Code 03/04H)
24
Execute Operation (Function Code 05H)
25
Store Single Setting (Function Code 06H)
25
Store Multiple Settings (Function Code 10H)
26
Exception Responses
26
File Transfers
27
Obtaining Relay Files Using Modbus
27
Memory Map
32
Modbus Memory Map
32
6 Iec 60870-5-104
80
Communication
81
Data Formats
203
3 Iec 61850 Communication
239
Overview
239
Introduction
239
Abstract Communication Service Interface (ASCI)
241
Datasets
244
Txgoose
245
Rxgoose
247
Reports
248
Commands
250
Substation Configuration Language (SCL)
250
Configuring the UR Using SCL
256
Merge SCL File
261
Configurable Logical Devices
262
Protocol Implementation Conformance Statement (PICS)
262
Basic Conformance Statement
262
ACSI Conformance Statement
263
ACSI Basic Conformance Statement
263
ACSI Models Conformance Statement
263
ACSI Services Conformance Statement
265
Model Implementation Conformance Statement (MICS)
267
Master (Root) Logical Device
268
Protection (Prot) Logical Device
275
Control (Ctrl) Logical Device
351
System Logical Device
385
Meter Logical Device
406
General (Gen) Logical Device
426
GE Namespace
442
Enumerations
457
SCL Implementation Conformance Statement (SICS)
458
PIXIT Conformance Statement
460
TICS Conformance Statement
465
SCL Logging
467
Overview of Process
467
SCL File Storage on UR
468
Generation of CID Files
468
Schema Version Used by Ur/Enervista
468
CID File Processing Steps
468
SCL Log File Format and Examples
468
Troubleshooting Log File Errors
470
G2 Implementation Model for GOOSE Configuration Via SCL
470
Introduction
470
Configuration Process
471
Configuration Process with IED Setup Tool
473
IED Capability Description (ICD) File
473
Instantiated IED Capability Description (IID) File
477
Configured IED Description (CID) File
477
Sample SCL Files
479
Annex - Optional Intermediate GOOSE Reception Objects
484
E3-2.0 Implementation Model for GOOSE Configuration Via SCL
487
Introduction
487
Workflow
487
ICD Files
488
CID Files
489
IID Files
490
Advertisement
Related Products
GE Baker Hughes Masonelian BR200
GE Baker Hughes Masonelian BR400
GE B90 UR Series
GE Monogram BCS42C
GE Power Break
GE Baker Hughes Masoneilan SVI FF
GE BC-375-E
GE CARESCAPE B650
GE AKR B 50H Series
GE B40
GE Categories
Refrigerator
Ranges
Microwave Oven
Air Conditioner
Dishwasher
More GE Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL