GE B30 Communications Manual page 254

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

OVERVIEW
13110
13111
13112
13113
13114
13115
" bufTime="Dyn/Conf " trgOps="Dyn/Conf " intgPd="Dyn/Conf "/>
13116
13117
13118
13119
13120
13121
13122
</Services>
3
For Edition 1, the Services content is as follows:
<Services>
<SettingGroups>
<SGEdit/>
</SettingGroups>
<GetDirectory/>
<GetDataObjectDefinition/>
<DataObjectDirectory/>
<GetDataSetValue/>
<DataSetDirectory/>
<ConfDataSet max="18" maxAttributes="64"/>
<ReadWrite/>
<ConfReportControl max="48"/>
<GetCBValues/>
<ReportSettings cbName="Conf" datSet="Conf" rptID="{ReportSettings rptID setting value}"
optFields="{ReportSettings optFields setting value}" bufTime="{ReportSettings bufTime setting value}"
trgOps="{ReportSettings trgOps setting value}" intgPd="{ReportSettings intgPd setting value}"/>
<GSESettings cbName="Conf" datSet=" Conf" appID="Conf"/>
<ConfLNs fixPrefix="true" fixLnInst="true"/>
<GOOSE max="16"/>
<FileHandling/>
</Services>
The "ReportSettings" element attributes "rptID," "optFields," "bufTime," "trgOps," and "intgPd" are configurable under
Settings > Product Setup > Communications > IEC 61850 > Reports > Report Settings to either "Dyn" or "Conf."
Next in the IED element is the AccessPoint element, which describes the information model visible through Ethernet port 1.
Following this AccessPoint element are AccessPoint elements for Ethernet ports 2 and 3, each of which declares that it has
the same information model by referencing the first AccessPoint element. This first AccessPoint element contains an
LDevice element for each logical device in the IED. Each LDevice element contains an LN0 or LN element for each logical
node in that logical device. Each LN0 and LN element contains for each of its control blocks and data objects an element
defining that control block or data object. In IID files for URs in which datasets have been configured, each dataset has an
element defining that dataset also included here. The following code shows the first AccessPoint, its first logical device,
first logical node, and first dataset.
13123
<AccessPoint name ="S1">
13124
13125
13126
13127
13128
13129
doName="PhyHealth" daName="stVal" fc="ST"/>
3-16
<DataSetDirectory/>
<ConfDataSet max="18" maxAttributes="64"/>
<ReadWrite/>
<ConfReportControl max="48"/>
<GetCBValues/>
<ReportSettings cbName="Conf" datSet="Conf" rptID="Dyn/Conf" optFields="Dyn/Conf
<GSESettings datSet="Conf" appID="Conf"/>
<ConfLNs fixPrefix="true" fixLnInst="true"/>
<ConfLdName/>
<GOOSE max="16"/>
<FileHandling/>
<SupSubscription maxGo="64" maxSv="0"/>
<Server>
<Authentication none = "true"/>
<LDevice inst="Master" >
<LN0 lnType="LLN0_0" lnClass="LLN0" inst="">
<DataSet name="TT6DataSet1" eGE:Label="TT6DataSet1">
<FCDA ldInst="Master" prefix="lnClass="LPHD" lnInst="1"
CHAPTER 3: IEC 61850 COMMUNICATION
UR FAMILY – COMMUNICATIONS GUIDE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents