GE B30 Communications Manual page 166

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MEMORY MAP
Products
Address Register name
"
9E65
"
9E8A
Charge Current Compensation Settings (Read/Write Grouped Setting)
L60
9EF0
"
9EF1
"
9EF3
2
"
9EF4
Undercurrent (Read/Write Grouped Setting)
M60
9F00
"
9F01
"
9F02
"
9F03
"
9F04
"
9F05
"
9F06
"
9F07
"
9F09
"
9F0A
"
9F0B
"
9F0C
"
9F0D
"
9F0E
"
9F0F
"
9F10
"
9F11
"
9F13
Cold Load Pickup (Read/Write Setting) (2 or 6 Modules)
F35, F60
9F30
"
9F31
"
9F33
"
9F35
"
9F36
"
9F38
"
9F39
"
9F3A
F35
9F44
"
9F4E
"
9F58
"
9F62
B90 Direct Outputs (Read/Write Setting) (256 Modules)
B90
A000
"
A002
"
A003
"
A006
"
A009
2-146
...Repeated for Voltage Differential 2
...Repeated for Voltage Differential 3
Charging Current Compensation Factor
Charging Current Compensation Block
Charging Current Compensation Positive-
Sequence Xc
Charging Current Compensation Zero-
Sequence Xc
Undercurrent (Speed 1) Function
Undercurrent (Speed 1) Start Block Delay
Undercurrent (Speed 1) Alarm Pickup
Undercurrent (Speed 1) Alarm Pickup Delay 0 to 600
Undercurrent (Speed 1) Trip Pickup
Undercurrent (Speed 1) Trip Pickup Delay
Undercurrent (Speed 1) Trip Reset Delay
Undercurrent (Speed) 1 Block
Undercurrent Target
Undercurrent Events
Undercurrent Speed 2 Start Block Delay
Undercurrent Speed 2 Alarm Pickup
Undercurrent Speed 2 Alarm Pickup Delay
Undercurrent Speed 2 Trip Pickup
Undercurrent Speed 2 Trip Pickup Delay
Undercurrent Speed 2 Trip Reset Delay
Undercurrent Speed 2 Block
Reserved (2 items)
Cold Load Pickup 1 Function
Cold Load Pickup 1 Initiate
Cold Load Pickup 1 Block
Outage Time Before Cold Load Pickup 1
On Load Time Before Reset 1
Cold Load Pickup 1 Source
Cold Load Pickup 1 Reserved
...Repeated for Cold Load Pickup 2
...Repeated for Cold Load Pickup 3
...Repeated for Cold Load Pickup 4
...Repeated for Cold Load Pickup 5
...Repeated for Cold Load Pickup 6
Direct Output 1 Operand
Direct Output 1 Events
...Repeated for Direct Output 2
...Repeated for Direct Output 3
...Repeated for Direct Output 4
CHAPTER 2: MODBUS COMMUNICATION
Range
Units
Step
0 to 1
---
1
0 to 4294967295
---
1
0.1 to 65.535
kOhm
0.001 F001
0.1 to 65.535
kOhm
0.001 F001
0 to 1
---
1
0 to 600
s
0.01
0.1 to 0.95
× FLA
0.01
s
0.01
0.1 to 0.95
× FLA
0.01
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 2
---
1
0 to 1
---
1
0. to 600
s
0.01
0.1 to 0.95
× FLA
0.01
0 to 600
s
0.01
0.1 to 0.95
× FLA
0.01
0 to 600
s
0.01
0 to 600
s
0.01
0 to 4294967295
---
1
0 to 1
---
1
0 to 1
---
1
0 to 4294967295
---
1
0 to 4294967295
---
1
0 to 1000
s
1
0 to 1000000
s
0.001 F003
0 to 5
---
1
0 to 65535
---
1
0 to 4294967295
---
1
0 to 1
---
1
UR FAMILY – COMMUNICATIONS GUIDE
Format
Default
F102
0 (Disabled)
F300
0
100
100
F102
0 (Disabled)
F001
50
F001
70
F001
200
F001
70
F001
100
F001
100
F300
0
F109
0 (Self-reset)
F102
0 (Disabled)
F001
50
F001
70
F001
200
F001
70
F001
100
F001
100
F300
0
F001
0
F102
0 (Disabled)
F300
0
F300
0
F001
1000
100000
F167
0 (SRC 1)
F001
0
F300
0
F102
0 (Disabled)