SCL IMPLEMENTATION CONFORMANCE STATEMENT (SICS)
Table 3-225: SCL conformance statement
ICD Export
I11
Fix ICD file (no adaptable export needed)
I12
Export of ICD file or IID file according to IED
preconfiguration performed by tool
I13
State the data model name space (61850-7-3
subclause 7.2) within ICD file (LLN0.NamPlt.ldNs value)
I14
State the data model version (61850-7-3 subclause
7.8.3) and any predefined / fixed configuration values
within ICD file (9.5.4.4)
I15
Version 2003 export
3
I16
Version 2007 export
I17
Predefined data sets
I18
Predefined control blocks
I19
Substation bay template with IED part
I110
Communication section with default address
I111
Export correct valKind value (Table 46)
I112
Exports internal addresses as InRef or Input section
(subclause 9.3.13)
I113
Exports internal addresses in Input section with
expected serviceType (subclause 9.3.13)
I114
Exports in UTF-8 coding
SCD import
I21
Identify IED to be configured in SCD file by IED name
I22
Configure LD name (at least via ldInst, dependent on
the IED capabilities) and IED addresses from SCD
I23
Determine communication side addresses of IED inputs
from SCD
I24
Determine and use clock communication addresses
from SCD
I25
Configure values of (existing) control block from SCD
(9.3)
I26
Prepare (new) control block instances according to SCD
file
I26
Prepare / configure data sets according to SCD file
I28
Modify predefined data sets according to SCD
I29
Interpret client references in the control blocks of other
IEDs to find the control block instances allocated to this
IED, and data sent to this IED.
I210
Set IED configuration values and parameter values as
defined in SCD file
I211
Support changed (reduced capability) valKind (e.g. from
Set to RO or to Conf) (able 46)
I212
Support ldName on other IEDs (9.3.4)
I213
Interpret input signal references to source control
blocks (9.3.13)
I214
Imports UTF-8 coding of XML
IID export after IED engineering
3-226
CHAPTER 3: IEC 61850 COMMUNICATION
UR
UR Setup
Value/comments
firmware
software
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
If renamed
Yes
CID
Yes
Yes
IP address
is used to
locate the
IED name
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Where configurable
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes