GE B30 Communications Manual page 422

Universal relay family
Hide thumbs Also See for B30:
Table of Contents

Advertisement

MODEL IMPLEMENTATION CONFORMANCE STATEMENT (MICS)
LNName: ACsrcMMXN#
data obj. data attribute
units
units.SIUnit
units.multiplier
db
zeroDb
Table 3-196: AC signal sources data objects
LNName: ACsrcMSQI#
data obj. data attribute
SeqA
3
c1
c1.instCVal
c1.instCVal.mag.f FLOAT32
c1.instCVal.ang.f FLOAT32
c1.cVal
c1.cVal.mag.f
c1.cVal.ang.f
c1.units
c1.units.SIUnit
c1.units
.multiplier
c1.db
c1.dbAng
c1.zeroDb
c2
c2.instCVal
c2.instCVal.mag.f FLOAT32
c2.instCVal.ang.f FLOAT32
c2.cVal
c2.cVal.mag.f
c2.cVal.ang.f
c2.units
c2.units.SIUnit
c2.units
.multiplier
c2.db
c2.dbAng
c2.zeroDb
c3
c3.instCVal
c3.instCVal.mag.f FLOAT32
c3.instCVal.ang.f FLOAT32
c3.cVal
c3.cVal.mag.f
c3.cVal.ang.f
c3.units
c3.units.SIUnit
3-184
LDevice inst: Meter
UR element: AC Source #
Type
FC UR Name
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MMXN# RMS GndCur
DEADBAND
INT32U
CF
LDevice inst: Meter
UR element: AC Source #
Type
FC UR Name
SEQ
CMV
Vector
MX
SRC # Positive Sequence Current
Magnitude
SRC # Positive Sequence Current
Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MSQI# Seq1 Cur.db
INT32U
CF
MSQI# Seq1 Cur.dbAng
INT32U
CF
CMV
Vector
MX
SRC # Negative Sequence
Current Magnitude
SRC # Negative Sequence
Current Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
ENUMERATED
INT32U
CF
MSQI# Seq2 Cur.db
INT32U
CF
MSQI# Seq2 Cur.dbAng
INT32U
CF
CMV
Vector
MX
SRC # Zero Sequence Current
Magnitude
SRC # Zero Sequence Current
Angle
Vector
MX
FLOAT32
FLOAT32
Unit
CF
ENUMERATED
CHAPTER 3: IEC 61850 COMMUNICATION
Description
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
Description
SRC # Sequence Current phasors, in
primary amperes
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
0, the code for a multiplier of 1
current cut-off level.
UR range -180...+180 converted to 0...360 R
instCVal.mag.f deadbanded
instCVal.ang.f deadbanded
5, the code for primary amperes
UR FAMILY – COMMUNICATIONS GUIDE
R/W/C
R
R
R
R/W/C
R
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R
R
R/W/C
R/W/C
R
R
R
R
R
R
R
R
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents